Thoracic and Cardiovascular Surgeon 2006-Jun

C1-INH and its effect on infarct size and ventricular function in an acute pig model of infarction, cardiopulmonary bypass, and reperfusion.

Само регистровани корисници могу преводити чланке
Пријави се / Пријави се
Веза се чува у привремену меморију
C Schreiber
W Heimisch
H Schad
A Brkic
C Badiu
R Lange
R Bauernschmitt

Кључне речи

Апстрактан

BACKGROUND

Recent studies suggest that complement inhibition reduces reperfusion injury. A clinical setting with local application of a C1 esterase inhibitor (C1-INH) has been modeled in an animal study in order to further investigate these findings.

METHODS

In 21 pigs, the left anterior descending coronary artery (LAD) was occluded distally to the first diagonal branch for 2 hours (h), including 1 h of cardioplegic arrest during CPB. After release of the coronary snare, C1-INH or NaCl (control) was applied to the aortic root. Thereafter, the aortic cross-clamp was removed and the heart was reperfused for 30 minutes before weaning from CPB. Left ventricular pressure volume analysis was performed by a multielectrode conductance catheter and the area at risk and infarct size were determined from excised hearts.

RESULTS

The following data were observed (mean+/-SEM) for the control group and the C1-INH group, respectively, after 1-h ligation of the LAD: heart rate (HR) 86+/-3 and 93+/-6 beats/min, stroke volume (SV) 1.2+/-0.1 and 1.2+/-0.1 ml/kg, aortic pressure (AoP) 83+/-6 and 87+/-5 mmHg, left ventricular end-diastolic pressure (LVedP) 12+/-1 and 11+/-2 mmHg; two hours after weaning from CPB: HR 106+/-9 and 123+/-4 beats/min, SV 0.9+/-0.1 and 0.9+/-0.1 ml/kg, AoP 65+/-5 and 79+/-7 mmHg, LVedP 9+/-1 and 8+/-1 mmHg. Conductance catheter measurements showed no improved left ventricular performance after C1-INH application. Infarct size to area at risk ratio was 61.5+/-4.2% for controls and 61.4+/-4.8% for C1-INH.

CONCLUSIONS

Intracoronary application of complement inhibitor in an acute infarction model, which mimicked a clinical setting of urgent coronary bypass grafting after ischemia, has been shown to neither influence the area of infarction, nor the ventricular function.

Придружите се нашој
facebook страници

Најкомплетнија база лековитог биља подржана науком

  • Ради на 55 језика
  • Биљни лекови потпомогнути науком
  • Препознавање биљака по слици
  • Интерактивна ГПС мапа - означите биље на локацији (ускоро)
  • Читајте научне публикације повезане са вашом претрагом
  • Претражите лековито биље по њиховим ефектима
  • Организујте своја интересовања и будите у току са истраживањем вести, клиничким испитивањима и патентима

Упишите симптом или болест и прочитајте о биљкама које би могле да помогну, укуцајте неку биљку и погледајте болести и симптоме против којих се користи.
* Све информације се заснивају на објављеним научним истраживањима

Google Play badgeApp Store badge