Serbian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Acta pharmacologica et toxicologica 1986

Factors of importance for valid digitalis assays particularly for the determination of digoxin in plasma and urine.

Само регистровани корисници могу преводити чланке
Пријави се / Пријави се
Веза се чува у привремену меморију
L Molin

Кључне речи

Апстрактан

Four commercial radioimmunoassay (RIA) kits for digoxin varied in precision (coefficient of variation, CV within-assays 5-14%) and accuracy (up to 40%). Thus it seems that such commercial RIA-kits can reach at best a CV within-assay of 5% and a similar variation between assays. Without a good control of the performance, the variation can increase 5-6 times. We found that the precision of digoxin RIA as performed at 27 Swedish laboratories using 10 different methods varied from 0.05 to 0.61 nmol/L in between-assay SD for a pool of 2.60 nmol/L. Up to 100% deviations between the highest and lowest reported concentration of a spiked plasma pool may occasionally occur. Such deviations mostly depend on the laboratory, but there are contributions from the kit and effects of the matrix as well. Matrix effects were observed in plasma samples from patients with uremia, acute myocardial infarction and treated with spironolactone to which digoxin was added to a concentration of 2.50 nmol/L. We found 10% underestimation by one method, 10% overestimation by two methods and 5% overestimation by a fourth method, respectively, with the above described samples. For a good judgement of a found plasma concentration value, calculation of a confidence interval is useful. This can be done by computer fitting of the standard curve after duplicate runs of standards and samples in random order. One source of error in RIA appears to be the use of inaccurate standards. We found that standards provided with different RIA-kits for digoxin varied up to 30%. Various physicochemical properties of cardiac glycosides, which could influence the assays were studied. Both digitoxin and digoxin are sparsely soluble in water (5.1 and 36 mumol/L, respectively). Methanol is a much better solvent, which dissolves 6.9 mmol/L of digoxin and 20-24 mmol/L of digitoxin. Chloroform is a good solvent for digitoxin (29-34 mmol/L) but not for digoxin (0.42 mmol/L). Partition of cardenolides between chloroform and water reflected their lipophilic or hydrophilic character. Thus, digitoxin had a high affinity to the organic phase (distribution constant KD = 10(3.65)), while the hydrophilic deslanoside was preferentially found in the aqueous phase (KD = 10(-3.08). Interestingly, the sugar moiety digitoxose in the digoxin molecule turned out to be a substituent that increased lipophilicity. Adsorption of cardiac glycosides occurs to plastics and glass from aqueous solutions. To overcome losses at low concentrations, the solutions must contain plasma, albumin, alcohol or similar solubility-increasing ingredients.(ABSTRACT TRUNCATED AT 400 WORDS)

Придружите се нашој
facebook страници

Најкомплетнија база лековитог биља подржана науком

  • Ради на 55 језика
  • Биљни лекови потпомогнути науком
  • Препознавање биљака по слици
  • Интерактивна ГПС мапа - означите биље на локацији (ускоро)
  • Читајте научне публикације повезане са вашом претрагом
  • Претражите лековито биље по њиховим ефектима
  • Организујте своја интересовања и будите у току са истраживањем вести, клиничким испитивањима и патентима

Упишите симптом или болест и прочитајте о биљкама које би могле да помогну, укуцајте неку биљку и погледајте болести и симптоме против којих се користи.
* Све информације се заснивају на објављеним научним истраживањима

Google Play badgeApp Store badge