Serbian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Helminthology 2005-Sep

Urinary schistosomiasis on Zanzibar: application of two novel assays for the detection of excreted albumin and haemoglobin in urine.

Само регистровани корисници могу преводити чланке
Пријави се / Пријави се
Веза се чува у привремену меморију
D Rollinson
E V Klinger
A F Mgeni
I S Khamis
J R Stothard

Кључне речи

Апстрактан

As part of a urinary schistosomiasis control programme on Zanzibar, an aged cross-sectional survey of 305 children from three schools on Unguja was conducted to investigate the relationships between levels of excreted albumin and haemoglobin in urine and Schistosoma haematobium infection status. Diagnosis was determined by standard parasitological methods, dipstick reagents for microhaematuria, visual inspection for macrohaematuria as well as collection of case-history questionnaire data for self-diagnosis. Prevalence of infection as determined by parasitology was 53.9% and approximately, one quarter of the children examined were anaemic (<11 g dl(-1)). A statistically significant negative association of blood haemoglobin levels of boys and S. haematobium infection intensity status was observed (rs=-0.23, P=0.005). Through sensitivity analysis of urine-albumin values it was determined that a concentration of above >40 mg l(-1), as measured with the HemoCue urine-albumin photometer, had sensitivity, specificity, positive and negative predictive values of 0.90, 0.83, 0.86 and 0.89 respectively against 'gold-standard' parasitology. There was a clear association of reported pain upon micturition for children with elevated urine-albumin levels, with an odds ratio of 20 to 1. Levels of excreted blood in urine were quantified with the HemoCue Plasma/Low Hb photometer. However, dipsticks remain the method of choice for urine-haemoglobin of 0.1 g l(-1) and below. Urine parameters over a 24-h period were assessed in a small sub-sample. Reductions in both albumin and haemoglobin excretion were observed in 11 children 54 days after praziquantel treatment. It was concluded that these rapid, high-through-put, portable HemoCue assays could play a role in better describing and monitoring the occurrence, severity and evolution of urinary schistosomiasis disease. The urine-albumin assay has particular promise as a biochemical marker of S. haematobium induced kidney- and upper urinary tract-morbidity.

Придружите се нашој
facebook страници

Најкомплетнија база лековитог биља подржана науком

  • Ради на 55 језика
  • Биљни лекови потпомогнути науком
  • Препознавање биљака по слици
  • Интерактивна ГПС мапа - означите биље на локацији (ускоро)
  • Читајте научне публикације повезане са вашом претрагом
  • Претражите лековито биље по њиховим ефектима
  • Организујте своја интересовања и будите у току са истраживањем вести, клиничким испитивањима и патентима

Упишите симптом или болест и прочитајте о биљкама које би могле да помогну, укуцајте неку биљку и погледајте болести и симптоме против којих се користи.
* Све информације се заснивају на објављеним научним истраживањима

Google Play badgeApp Store badge