Swedish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
PeerJ 2016

A simple and rapid method for measuring α-D-phosphohexomutases activity by using anion-exchange chromatography coupled with an electrochemical detector.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Xiaochen Jia
Jian Kang
Heng Yin

Nyckelord

Abstrakt

The interconversion of hexose-6-phosphate and hexose-1-phosphate can be directly analyzed by high-performance anion-exchange chromatography coupled with an electrochemical detector (HPAEC-PAD). Thus, this method can be used to measure the activities of N-acetylglucosamine-phosphate mutase (AGM), glucosamine-phosphate mutase (GlmM) and phosphoglucomutase (PGM), which are the members of α-D-phosphohexomutases superfamily. The detection limits were extremely low as 2.747 pmol, 1.365 pmol, 0.512 pmol, 0.415 pmol, 1.486 pmol and 0.868 pmol for N-acetylglucosamine-1-phosphate (GlcNAc-1-P), N-acetylglucosamine-6-phosphate (GlcNAc-6-P), glucosamine-1-phosphate (GlcN-1-P), glucosamine-6-phosphate (GlcN-6-P), glucose-1-phosphate (Glc-1-P) and glucose-6-phosphate (Glc-6-P), respectively. By employing HPAEC-PAD, activities of AtAGM (AGM from Arabidopsis thaliana) on these six phosphohexoses can be detected. The Km of AtAGM on Glc-1-P determined by HPAEC-PAD was 679.18 ± 156.40 µM, which is comparable with the Km of 707.09 ± 170.36 µM detected by traditional coupled assay. Moreover, the activity of MtGlmM (GlmM from Mycobacterium tuberculosis) on GlcN-6-P tested by HPAEC-PAD was 7493.40 ± 309.12 nmol∕min ⋅ mg, which is much higher than 288.97 ± 35.28 nmol∕min ⋅ mg obtained by the traditional coupled assay. Accordingly, HPAEC-PAD is a more rapid and simple method than the traditional coupled assays given its high specificity and sensitivity, and will certainly bring convenience to further research of α-D-phosphohexomutases.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge