Applied Spectroscopy 2008-Jan

Development of a rapid on-line acetylene sensor for industrial hydrogenation reactor optimization using off-axis integrated cavity output spectroscopy.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Linh D Le
J D Tate
Mary Beth Seasholtz
Manish Gupta
Thomas Owano
Doug Baer
Trevor Knittel
Alan Cowie
Jie Zhu

Nyckelord

Abstrakt

A spectroscopic analyzer has been developed for rapid, accurate quantification of acetylene and methyl acetylene in hydrocarbon cracked gas processing plants. The system utilizes off-axis integrated output cavity spectroscopy to measure the near-infrared, cavity-enhanced absorption spectrum of ethylene, methyl acetylene, and acetylene and employs a chemometric data analysis strategy to quantify the respective constituents. Initial tests verified that the instrument is capable of measuring, <0.050 ppmv of acetylene, has a precision of +/-0.025 ppmv, and can accurately determine acetylene concentrations with comparable accuracy to a gas chromatograph (+/-0.1 ppmv) in an actual process stream composition matrix under plant operating conditions. Subsequently, the prototype analyzer was installed in a hydrocarbon facility for field-trials, where its rapid response (< or =30 seconds or better) allowed it to measure transient acetylene and methyl acetylene fluctuations that were too fast for conventional methodologies. Moreover, the analyzer showed an extended dynamic range that enabled measurement of very high acetylene levels (0-1000 ppmv) during abnormal plant operations. Finally, two commercial acetylene analyzer systems with stream-switching capabilities were implemented in an industrial facility and initial results are presented.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge