Tanaffos 2015

Efficacy of the New Perilaryngeal Airway (CobraPLA™) Versus the Laryngeal Mask Airway (LMA™) to Improve Oropharyngeal Leak Pressure in Obese and Overweight Patients.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Siamak Yaghoobi
Seyed Mohamadreza Abootorabi
Hamid Kayalha
Tom C Van Zundert
Amir H Pakpour

Nyckelord

Abstrakt

BACKGROUND

This study aimed to evaluate the applicability of Cobra perilaryngeal airway (Cobra PLA™) for obese patients under general anesthesia and also to compare the results with those of classic laryngeal mask airway (LMA™).

METHODS

Seventy-three overweight and obese patients were included in this study. The patients were randomly assigned to LMA™ or Cobra PLA™ groups. Time required for intubation, successful intubation attempt, airway sealing pressure and incidence of complications including blood staining, sore throat and dysphagia were assessed and noted.

RESULTS

Thirty-six and 37 patients were randomly allocated to LMA™ and Cobra PLA™ groups, respectively. Most patients were males and had Mallampati Class II airway in both groups. The first attempt and overall insertion success for Cobra PLA™ was significantly higher compared to LMA (P<0.05). Airway insertion was more successful (P = 0.027; 94% vs. 77%) with Cobra PLA™. Insertion times were similar with Cobra PLA™ and LMA™ (Cobra PLA™, 29.94±16.35s; LMA™, 27.00±7.88s). The oropharyngeal leak pressure in the Cobra PLA™ group (24.80±0.90 H2O) was significantly higher than that in LMA™ group (19±1 H2O, p<0.001). Sore throat was more frequent in the LMA™ group although it did not reach statistical significance (Fisher's exact test, P = 0.33). Blood staining on airway tube was seen in both groups with a higher incidence in the Cobra PLA™ group (Fisher's Exact test, P = 0.02). Incidence of dysphagia was not different between the two groups.

CONCLUSIONS

CobraPLA™ was found to be safe with low complications. It provided better airway sealing with high rate of the first insertion success for use in obese and overweight patients. This study recommends the use of CobraPLA™ as a rescue device in emergency situations for obese and overweight patients.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge