Gastrointestinal Endoscopy 2015-Feb

Endoscopic gastric volume reduction with a novel articulating plication device is safe and effective in the treatment of obesity (with video).

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Tessa Verlaan
Givan F Paulus
Elisabeth M H Mathus-Vliegen
Elisabeth A M L Veldhuyzen
José M Conchillo
Nicole D Bouvy
Paul Fockens

Nyckelord

Abstrakt

BACKGROUND

Endoscopic volume reduction of the stomach may provide a minimally invasive alternative for surgical procedures in the treatment of obesity.

OBJECTIVE

To assess safety and preliminary effectiveness in the first human application of a novel endoscopic stapling technique.

METHODS

Prospective, observational, phase 1 study.

METHODS

Two university hospitals in The Netherlands.

METHODS

Patients with a body mass index (BMI) of 40 to 45 kg/m(2) or 30 to 39.9 kg/m(2) with obesity-related comorbidity.

METHODS

Gastric volume reduction with an endoscopic stapler.

METHODS

Primary outcome measure was the prevalence of serious or mild adverse events. Reduction of excess body weight after 12 months was assessed as a secondary outcome measure for effectiveness of the procedure.

RESULTS

Seventeen patients with a median BMI of 40.2 kg/m(2) (interquartile range [IQR] 37.6-42.8) underwent an endoscopic stapling procedure. Median procedure time was 123 minutes (IQR 95-129). No serious adverse events occurred. Adverse events were gastric pain (n = 7, range 1-3 days), sore throat (n = 4, 2-3 days), diarrhea (n = 4, 2-15 days), nausea (n = 3, 2-4 days), constipation (n = 4, 3-14 days), and vomiting (n = 3, 1-4 days). All adverse events were mild and resolved with conservative treatment within 15 days after surgery. The median percentage excess weight loss in the first year was 34.9% (IQR 17.8-46.6).

CONCLUSIONS

Limited number of patients.

CONCLUSIONS

This first human application of this endoscopic stapler demonstrates that the procedure is technically feasible and safe. One hundred sixty plications were created in 17 patients without significant problems. Weight loss after 1 year is promising, but long-term follow-up and randomized, controlled studies should evaluate whether this procedure is an effective and durable minimally invasive endoscopic treatment for obesity. (

BACKGROUND

NCT01429194.).

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge