Swedish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Pediatric Orthopaedics 2013-Mar

Interobserver variability using a commercially available system of archived digital radiography with integrated computer-assisted measurements for scoliosis Cobb angles.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Christina K Hardesty
James Aronson
Elizabeth A Aronson
Ashish S Ranade
Courtney W McCracken
Todd G Nick
Cari L Cordell

Nyckelord

Abstrakt

BACKGROUND

The purpose of this study was to determine if digital enhancements could improve upon published and interobserver variability for Cobb angle measurements of idiopathic scoliosis using a commercially available PACS system. The study also sought to determine if experience of the observer affected overall variability and to evaluate the time required to measure Cobb angles using 3 different techniques. As the decision for scoliosis treatment requires serial radiographic measurements by 1 or more observers at different times, precise landmark identification and curve measurement should decrease variability and improve accuracy.

METHODS

Fifty-four consecutive digital radiographs of 49 children with idiopathic scoliosis were collected and archived, yielding a total of 117 curves. Five observers, ranging from a PGY2 resident to a senior level faculty member, measured each radiograph in 3 different ways. Technique A involved measuring the curves as the image first appeared on the computer screen. Technique B consisted of 2 extra steps: enlarging the image until the spine filled the screen and using an edge enhancement tool. Technique C utilized the steps in B and further enlarging each vertebra to adjust each measurement. Each technique was timed for each observer.

RESULTS

Technique C had the lowest variability that was significantly different from technique A. Technique B also had lower variability than technique A. The 2 observers with the greatest experience demonstrated the least intraobserver and interobserver variability. Techniques B and C decreased the variability of less experienced observers. The average time required for techniques A, B, and C was 25, 29, and 40 seconds, respectively. Confounding variables such as obesity did not affect the measurements, but curve location did, with thoracic curves causing greater variability for less experienced observers.

CONCLUSIONS

The results demonstrate that less experienced observers using the relatively rapid technique A for digital radiographs are more likely to have clinically significant discrepancies in their measurements, which could affect treatment decisions. Taking 4 extra seconds using technique B significantly decreases variability and improves accuracy in the evaluation and management of scoliosis patients.

METHODS

I (testing of previously developed diagnostic criteria).

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge