American Journal of Roentgenology 2014-Mar

Low-dose CT with automatic tube current modulation, adaptive statistical iterative reconstruction, and low tube voltage for the diagnosis of renal colic: impact of body mass index.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Alban Gervaise
Pierre Naulet
Florence Beuret
Christelle Henry
Matthieu Pernin
Yann Portron
Marie Lapierre-Combes

Nyckelord

Abstrakt

OBJECTIVE

The objective of our study was to evaluate the impact of body mass index (BMI) on dose, diagnostic performance, and image quality of a low-dose CT examination for renal colic.

METHODS

This retrospective study included all patients who underwent a low-dose CT examination for renal colic performed during the year 2012 with automatic tube current modulation, adaptive statistical iterative reconstruction, and a low tube voltage (kV). Three readers independently reviewed all images for the presence of renal colic and evaluated diagnostic confidence and image quality. The results and doses were compared among patients grouped by body mass index (BMI) and between patients with a BMI<25 and those with a BMI≥25.

RESULTS

Eighty-six patients were included in the study: 39 patients had a BMI<25 and 47 had a BMI≥25. No statistically significant difference was found between the accuracy rates for the diagnosis of renal colic when the rates of the three independent readers were averaged for both BMI groups (95.7% vs 96.4%, respectively; p=0.83). Image quality and diagnostic confidence scores were significantly better for patients with a BMI≥25 than for patients with a BMI<25 (mean image quality score, 3.7 vs 3.4, p<0.001; mean diagnostic confidence score, 2.8 vs 2.5, p<0.001). The mean radiation dose for patients with a BMI<25 was 2.4 mGy compared with 3.7 mGy for patients with a BMI≥25 (p<0.001).

CONCLUSIONS

The diagnostic performance of our low-dose CT protocol for renal colic was excellent for all patients, and image quality and diagnostic confidence were significantly better for patients with a BMI≥25. However, our protocol also required exposure to a greater dose of radiation for these overweight and obese patients.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge