Swedish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Letters 2017

Novel Imprinted Polymer for the Preconcentration of Cadmium with Determination by Inductively Coupled Plasma Mass Spectrometry.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Vedat Yilmaz
Hayriye Yilmaz
Zikri Arslan
Jerzy Leszczynski

Nyckelord

Abstrakt

A novel Cd(II)-imprinted polymer was prepared with chemical immobilization approach by using N-methacryloyl-L-histidine as a vinylated chelating agent for on-line solid phase extraction of Cd(II) for determination by inductively coupled plasma mass spectrometry. Cd(II)-monomer complex was synthesized and copolymerized via bulk polymerization method in the presence of ethyleneglycoldimethacrylate cross-linker. The resulting polymer was leached with 1.0 mol L-1 HNO3 to generate the cavities in the polymer for Cd(II) ions. The experimental conditions, including load pH, solution flow rate, and eluent concentration for effective sorption of Cd(II) were optimized using a minicolumn of the imprinted polymer. A volume of 5.0 mL sample 5 μg L-1 Cd(II) solution at pH 6.5 was loaded onto the column at 2.0 mL min-1 by using a sequential injection system (FIALab 3200) followed by elution with 1.0 mL of 0.75 mol L-1 HNO3. The relative selectivity coefficients of the imprinted polymer for Cd(II) were 38.5, 3.5, 3.0, 2.5 and 6.0 in the presence of Cu(II), Ni(II), Zn(II), Co(II) and Pb(II), respectively. Computational calculations revealed that the selectivity of the imprinted polymer was mediated by the stability of Cd(II)-N-methacryloyl-L-histidine complex which was far more stable than those of commonly used monomers, such as 4-vinyl pyridine, methacrylic acid and vinylimidazole. The detection limit (3s) and relative standard deviation (%) were found to be 0.004 μg L-1 and 3.2%, respectively. The method was validated by analysis of seawater certified reference material (CASS-4) and successfully applied to the determination of Cd(II) in coastal seawater and estuarine water samples.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge