RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren 2009-Aug

[Onyx (ethylene-vinyl-alcohol-copolymer)--a novel approach to the endovascular treatment of acute bleeding].

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
R Müller-Wille
T Herold
E M Jung
J Rennert
P Heiss
M Lenhart
C Paetzel
S Feuerbach
N Zorger

Nyckelord

Abstrakt

OBJECTIVE

The purpose of our retrospective study was to determine the feasibility and efficacy of the endovascular embolization of peripheral acute arterial hemorrhage using Onyx.

METHODS

Between October 2003 and February 2007, 14 patients with acute arterial bleeding underwent percutaneous arterial embolization using Onyx. Bleeding was caused by iatrogenic vessel injury (6 patients), malignancy/inflammation (5 patients) and trauma (3 patients). Hematomas were located in the pelvis (5 patients), followed by liver (3 patients), retroperitoneal space (2 patients), thorax (2 patients), pancreas (1 patient), and thigh (1 patient). The number of embolized arteries, the volume and viscosity of embolic agent (Onyx), the number of additionally used coils, the embolization time, and the technical and clinical outcome were documented. Procedure-related complications, recurrent bleeding during hospital stay and outcome were recorded.

RESULTS

In 14 patients selective endovascular embolization of 15 arteries was performed. The average volume of injected Onyx was 1.3 +/- 0.8 ml. In 6 cases (42.9%) Onyx was used in conjunction with coils. The average time between the correct placement of microcatheter and complete embolization was 24.9 +/- 12.6 minutes. In 13 of 14 patients (92.8%), embolization was technically successful. In one case, procedure-related complications occurred and embolization was performed in a second session a day later. After technically successful embolization, no recurrent bleeding occurred during hospitalization. Out of 14 patients, six (42.9%) died 1 - 38 days after technically successful embolization due to multiple organ failure (2 patients), hypoxic brain injury (2 patients), septic shock (1 patient) or malignancy-associated death (1 patient).

CONCLUSIONS

We conclude that transcatheter embolization with the new liquid embolic agent Onyx is technically feasible and effective in patients with acute arterial hemorrhage.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge