Swedish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Analytical Toxicology 2017-Jun

Sensitive Determination of Cannabinoids in Whole Blood by LC-MS-MS After Rapid Removal of Phospholipids by Filtration.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Lambert K Sørensen
Jørgen B Hasselstrøm

Nyckelord

Abstrakt

Direct analysis of Δ9-tetrahydrocannabinol (THC) and other cannabinoids in crude acetonitrile extracts of whole blood by liquid chromatography-tandem mass spectrometry using pneumatically assisted electrospray ionization (LC-ESI-MS-MS) was subjected to pronounced ion suppression from co-eluting phospholipids (PLs). The interferences were mainly caused by the lysophosphatidylcholine and lysophosphatidylethanolamine classes of PLs. The PLs were easily removed from crude extracts by filtration through a sorbent with Lewis acid properties, which typically increased the THC and cannabinol (CBN) signal intensities by a factor of 5. Based on this technique, a simple high-throughput LC-MS-MS method was developed for the determination of cannabinoids in 100 μL samples of whole blood. The lower limits of quantification were 0.2 μg/L for THC, CBN, cannabidiol (CBD) and Δ9-tetrahydrocannabinolic acid A (THCA-A) and 0.5 μg/L for 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH). The mean ion suppression levels after clean-up were 10% (THC), 9% (CBN), 17% (CBD), 0% (THC-OH), 2% (THC-COOH) and 9% (THCA-A) at blood concentration levels of 1-10 μg/L. The mean true extraction recoveries were 97% (THC), 101% (CBN), 101% (CBD), 98% (THC-OH), 95% (THC-COOH) and 90% (THCA-A) at the same concentration levels. The relative intra-laboratory reproducibility standard deviations were <9% at concentrations of 1 μg/L or higher. The trueness expressed as the relative bias of the test results was within ±4% at concentrations of 1 μg/L or higher.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge