Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering 2007-Oct

[Study on a novel vascular stent material (titanium oxide, Ti-O) coated with albumin and heparin: is it hemocompatible with fibrinogen].

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Jie Song
Xi Wu
Nan Huang
Biao Xu
Fengjuan Jing
Junying Chen
Yongxiang Leng
Ping Yang
Jin Wang
Hong Sun

Nyckelord

Abstrakt

The functional hemocompatibility between fibrinogen (FIG) and a novel vascular stent material (Ti-O film fixed with albumin and heparin) was investigated as follows: (1) Preparing the new biologic material (Ti-O) film; (2) Coating albumin and heparin on the Ti-O film; (3) Testing platelets (PL) adsorption; (4) Determining FIG adhesion number by use of enzyme linked immunoassay (ELISA); (5) Implanting the films from the test group of Ti-O film and from the comparison group of stainless steel (SS) film into the left and right femoral arteries respectively in 4 dogs. It was proved that albumin and heparin were fixed on Ti-O film. After 6 months, the femoral arteries of the dogs were resected. In the test group of Ti-O film coated with albumin and heparin, few PL adhered to the coat, their form did not change, and no thrombus was found by scanning electron microscopy; the result was better than that of plain Ti-O film, and was much better than that of SS film. Ti-O maintained normal transformation condition of FIG, and no C terminal of gamma chain in FIG was revealed. As it is known whether the hemocompatibility of a biomaterial is good depends upon its adsorption of FIG, and Ti-O has excellent reaction on albumin and heparin by chemical processes. In this study, the Ti-O film coated with albumin and heparin further reduced the absorption of FIG and PL when compared against the plain Ti-O film. So the Ti-O film coated with albumin and heparin has the insistent and permanent anticoagulant character.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge