Clinical Physiology and Functional Imaging 2012-Mar

The washout rate of a subcutaneous 99mTc-HSA depot in lower extremity lymphoedema.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Mads R Jensen
Lene Simonsen
Tonny Karlsmark
Jens Bülow

Nyckelord

Abstrakt

OBJECTIVE

Lymphoscintigraphy is currently the leading diagnostic modality of lower extremity lymphoedema but has been criticized for being unreliable. Washout rate constants have been investigated and proven to be of diagnostic value in several studies of breast-cancer-related lymphoedema; however, the applicability in lower extremity lymphoedema needs further evaluation. The aim of the study was to verify if washout of (99m) Tc-human serum albumin ((99m) Tc-HSA) is a reliable diagnostic tool in lower extremity lymphoedema.

METHODS

Twenty healthy volunteers and eight patients (11 legs) with lymphoscintigraphy verified lower extremity lymphoedema participated in the study. A depot consisting of 0.1 ml 10 MBq/ml (99m) Tc-HSA was injected subcutaneously into the dorsum of each foot. The depot washout rate was measured using a portable scintillation detector system and time-activity curves were generated. After 30 min of supine rest and 10 min of standardized ergometric exercise, measurements were recorded for 20 min. Following correction for physical decay of (99m) Tc, the depot washout rate constant was calculated using linear regression analysis. Finally depot half-life was calculated from the washout rate constant.

RESULTS

Median half-life for healthy volunteers was 9.4 h (range 2.5-28.3 h). Median half-life for lymphoedema patients was 10.7 h (range 1.5-35.1 h). No statistical significant difference could be detected between healthy volunteers and lymphoedema patients (P = 0.78).

CONCLUSIONS

The washout rate of a subcutaneous (99m) Tc-HSA depot is not a reliable diagnostic tool in examination of lower extremity lymphoedema. Additional examinations revealed in vivo instability of the utilized (99m) Tc-HSA as the likely reason.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge