International Journal of Cardiology 2015-Sep

Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Jochen Wöhrle
Birgid Gonska
Christoph Rodewald
Ulrike Trepte
Sabrina Koch
Dominik Scharnbeck
Julia Seeger
Sinisa Markovic
Wolfgang Rottbauer

Nyckelord

Abstrakt

BACKGROUND

The rate of paravalvular aortic insufficiency (AI) with transcatheter aortic valve implantation (TAVI) with first generation devices was higher compared with surgical replacement. Residual AI after TAVI has been linked to an increased mortality rate. We compared two second generation TAVI devices - the repositionable Lotus valve with the balloon-expandable Edwards Sapien 3 valve - regarding procedural and 30 day outcome.

RESULTS

In 78 patients with severe aortic stenosis undergoing transfemoral TAVI we evaluated post-procedural paravalvular AI, device success and early safety according to VARC criteria. Valve size was based on a 256-multislice computed tomography. Patients were followed for 30 days. The Lotus valve (N = 26) and the Edwards Sapien 3 valve (N = 52) were implanted under fluoroscopic guidance. Baseline characteristics were similar between groups. Perimeter derived annulus diameter did not differ with 25.7 ± 1.6mm for Lotus and 25.2 ± 2.1mm for Edwards Sapien 3 patients. After TAVI aortography and transthoracic echocardiography revealed no moderate or severe AI. The rate of mild AI was 12% for Lotus and 15% for Edwards Sapien 3 (p = 0.62). There were no deaths, stroke, annulus rupture or coronary obstruction. Device success was 96% and 98% (p = 0.61), early safety according to VARC 11.5% in both groups (p = 1.0) and the need for pacemaker implantation 27% and 4% (p < 0.003), respectively.

CONCLUSIONS

TAVI with second-generation devices was associated with no moderate or severe AI and a low rate of mild AI. Device success was high for Lotus and Edwards Sapien 3 while the need for permanent pacemaker was significantly higher with the Lotus valve.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge