Swedish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Clinical Laboratory 2020-Mar

A Rapid Quantitative Chemiluminescence Immunoassay for Vitamin B12 in Human Serum.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Xiang Chen
Feng Ren
Jingjing Xu
Zheng Yu
Xuemei Lin
Zhonghu Bai
Fang Gong

Nyckelord

Abstrakt

Vitamin B12 is very important for the human body. Early diagnosis of vitamin B12 deficiency is essential because it is associated with many problems such as fatigue, lethargy, depression, poor memory, breathlessness, headaches, pale skin, mania, psychosis, etc. Most of the vitamin B12 molecules in serum bind to specific proteins as a complex; so, although researchers have developed some sensitive methods to quantify vitamin B12, few can be used for human serum detection of vitamin B12 because of disturbed releasing process. In this study, we are aiming to develop a rapid and accurate chemiluminescence immunoassay (CLIA) for human serum testing.In this study, we studied and optimized labelling of biotin molecules to vitamin B12 binding protein which had been extracted from hog gastric mucus, labelling of vitamin B12 molecules to horse radish peroxidase (HRP), releasing of vitamin B12 from its bound state in serum, concentrations of reagents, and incubation times.The developed method shows good performance and thermo-stability. The limit of detection (LOD) is 41 pg/mL, the recovery rate is 90.7% - 107.4%. The intra-assay CV is 4.4% - 8.0% and the inter-assay CV is 4.5% - 12.1%. Cross reactivity (CR) values are 49.4% for hydroxocobalamin and lower than 0.1% for vitamin B1, B2, B3, B9, and C. The method comparison results show that the correlation coefficient (R2) is 0.91, with a slight negative bias of -4.1% [95% limits of agreement (± 1.96 SD); -39.6% to 31.6%].The developed method shows high sensitivity and specificity and good correlation using a Beckman Coulter instrument while the whole test needs only 40 minutes. It can fully satisfy the very busy clinical labs.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge