Swedish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

anthrax/albumin

Länken sparas på Urklipp
ArtiklarKliniska testerPatent
Sida 1 från 20 resultat

Antibody responses to a spore carbohydrate antigen as a marker of nonfatal inhalation anthrax in rhesus macaques.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
The Bacillus anthracis exosporium protein BclA contains an O-linked antigenic tetrasaccharide whose terminal sugar is known as anthrose (J. M. Daubenspeck et al., J. Biol. Chem. 279:30945-30953, 2004). We hypothesized that serologic responses to anthrose may have diagnostic value in confirming

Recombinant HSA-CMG2 Is a Promising Anthrax Toxin Inhibitor.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Anthrax toxin is the major virulence factor produced by Bacillus anthracis. Protective antigen (PA) is the key component of the toxin and has been confirmed as the main target for the development of toxin inhibitors. The inhibition of the binding of PA to its receptor, capillary morphogenesis

Clinical features that discriminate inhalational anthrax from other acute respiratory illnesses.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Inhalational anthrax (IA) is a rapidly progressive disease that frequently results in sepsis and death, and prompt recognition is critical. To distinguish IA from other causes of acute respiratory illness, patients who had IA were compared with patients in an ambulatory clinic who had influenza-like

Square wave voltammetric detection of Anthrax utilizing a peptide for selective recognition of a protein biomarker.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
A short chain peptide (16mer) has been successfully utilized for the selective electrochemical detection of the protein biomarker, protective antigen (PA), for the diagnosis of Anthrax. The major motivation of using a peptide instead of an antibody for the development of a biosensor is that there

Anthrax lethal toxin induces endothelial barrier dysfunction.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Hemorrhage and pleural effusion are prominent pathological features of systemic anthrax infection. We examined the effect of anthrax lethal toxin (LT), a major virulence factor of Bacillus anthracis, on the barrier function of primary human lung microvascular endothelial cells. We also examined the
Sensitivity of Anthrax protective antigen (PA) detection has been improved by directly immobilizing a PA-specific peptide onto a multi-wall carbon nanotube (MWCNT). The MWCNT was covalently immobilized onto a polyaniline (PANI) electrode, which was prepared via electropolymerization of the aniline

Anthrax capsule vaccine protects against experimental infection.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Efficacy of a poly-gamma-D-glutamic acid anthrax capsule vaccine was assessed in a mouse model of infection. Capsule by itself was protective against lethal challenge with a toxin(-), capsule(+) Bacillus anthracis strain. Conjugation of capsule to bovine serum albumin resulted in enhanced IgG
Systemic anthrax disease is characterized by vascular leakage pathologies. We previously reported that anthrax lethal toxin (LT) induces human endothelial barrier dysfunction in a cell death-independent manner with actin stress fiber formation and disruption of adherens junctions (AJs). In the

Inhibition of anthrax lethal factor by ssDNA aptamers.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Anthrax is caused by Bacillus anthracis, a bacterium that is able to secrete the toxins protective antigen, edema factor and lethal factor. Due to the high level of secretion from the bacteria and its severe virulence, lethal factor (LF) has been sought as a biomarker for detecting bacterial

Nano aptasensor for protective antigen toxin of anthrax.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
We demonstrate a highly sensitive nano aptasensor for anthrax toxin through the detection of its polypeptide entity, protective antigen (PA toxin) using a PA toxin ssDNA aptamer functionalized single-walled carbon nanotubes (SWNTs) device. The aptamer was developed in-house by capillary

Screening and characterization of high-affinity ssDNA aptamers against anthrax protective antigen.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
The protective antigen (PA) of Bacillus anthracis is a secreted protein that functions as a critical virulence factor. Protective antigen has been selected as a biomarker in detecting bacterial infection. The in vitro selection method, systematic evolution of ligands by exponential enrichment

Strong antibody responses induced by protein antigens conjugated onto the surface of lecithin-based nanoparticles.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
An accumulation of research over the years has demonstrated the utility of nanoparticles as antigen carriers with adjuvant activity. Herein we defined the adjuvanticity of a novel lecithin-based nanoparticle engineered from emulsions. The nanoparticles were spheres of around 200nm. Model protein
BACKGROUND A common finding amongst patients with inhalational anthrax is a paucity of polymorphonuclear leukocytes (PMNs) in infected tissues in the face of abundant circulating PMNs. A major virulence determinant of anthrax is edema toxin (ET), which is formed by the combination of two proteins

Protective antigen detection using horizontally stacked hexagonal ZnO platelets.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Anthrax toxin detection before bacteremia, when toxin concentration is low, improves the chances of efficient treatment and cure. We present a novel technique for ultrasensitive detection of a protective antigen (PA(83)) of anthrax using an array of zinc oxide nanorods in conjunction with a

Low-level detection of a bacillus anthracis simulant using Love-wave biosensors on 36 degrees YX LiTaO3.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
We present an acoustic Love-wave biosensor for detection of the Bacillus anthracis simulant, Bacillus thuringiensis at or below inhalational infectious levels. The present work is an experimental study of 36 degrees YX cut LiTaO3 based Love-wave devices for detection of pathogenic spores in aqueous
Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge