Swahili
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Clinical Neurophysiology 2020-Jun

Limited-Montage EEG as a Tool for the Detection of Nonconvulsive Seizures

Watumiaji waliosajiliwa tu ndio wanaweza kutafsiri nakala
Ingia / Ingia
Kiungo kimehifadhiwa kwenye clipboard
Nicholas Swingle
Aditya Vuppala
Proleta Datta
Swetha Pedavally
Arun Swaminathan
Sachin Kedar
Kaeli Samson
Christopher Wichman
Jacob Myers
Olga Taraschenko

Maneno muhimu

Kikemikali

Purpose: Prefabricated arrays with a limited number of electrodes offer an opportunity to hasten the diagnosis of seizures; however, their accuracy to detect seizures is unknown. We examined the utility of two limited-montage EEG setups for the detection of nonconvulsive seizures.

Methods: Thirty previously interpreted EEG segments with nonconvulsive seizures from 30 patients and 60 segments with background slowing or normal EEG from 60 patients were rendered in a bipolar "double banana" montage, a double distance "neonatal" montage, and a circumferential "hatband" montage. Experts reviewed 60 to 180 seconds long segments to determine whether seizures were present and if the EEG data provided were sufficient to make a decision on escalation of clinical care by ordering an additional EEG or prescribing anticonvulsants. The periodic patterns on the ictal-interictal continuum were specifically excluded for this analysis to keep the focus on definite electrographic seizures.

Results: The sensitivities for seizure of the neonatal and hatband montages were 0.96 and 0.84, respectively, when compared with full montage EEG, whereas the specificities were 0.94 and 0.98, respectively. Appropriate escalation of care was suggested for 96% and 92% of occurrences of seizure patterns in neonatal and hatband montages, respectively. When compared with clinical EEG, the sensitivities of the neonatal and hatband montages for seizure diagnosis were 0.85 and 0.69, respectively.

Conclusions: Nonconvulsive seizures were detected with high accuracy using the limited electrode array configuration in the neonatal and hatband montages. The sensitivity of the neonatal montage EEG in detecting seizures was superior to that of a hatband montage. These findings suggest that in some patients with nonconvulsive seizures, limited-montage EEG may allow to differentiate ictal and slow patterns.

Jiunge na ukurasa
wetu wa facebook

Hifadhidata kamili ya mimea ya dawa inayoungwa mkono na sayansi

  • Inafanya kazi katika lugha 55
  • Uponyaji wa mitishamba unaungwa mkono na sayansi
  • Kutambua mimea kwa picha
  • Ramani ya GPS inayoshirikiana
  • Soma machapisho ya kisayansi yanayohusiana na utafutaji wako
  • Tafuta mimea ya dawa na athari zao
  • Panga maslahi yako na fanya tarehe ya utafiti wa habari, majaribio ya kliniki na ruhusu

Andika dalili au ugonjwa na usome juu ya mimea ambayo inaweza kusaidia, chapa mimea na uone magonjwa na dalili ambazo hutumiwa dhidi yake.
* Habari zote zinategemea utafiti wa kisayansi uliochapishwa

Google Play badgeApp Store badge