OBJECTIVE
To evaluate and compare the healing response related to two types of graft-covered Wallstents (WSs) and an uncovered WS in the canine iliac artery.
METHODS
Eight bare mesh WSs, 10 polyethylene terephthalate interbraided WSs (PET-WSs), and six polytetrafluoroethylene covered WSs (ePTFE-WSs)
OBJECTIVE
The occurrence of and the clinical picture of infection of transjugular intrahepatic portosystemic shunts (TIPS) has not been described previously. We describe the clinical features, associated pathogens, results of treatment of a previously unreported complication of TIPS, and primary