Turkish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Hellenic Journal of Nuclear Medicine

A false negative by planar scintigraphy liver hemangioma, diagnosed by technetium-99m-red blood cells and technetium-99m-sulfur colloid single photon emission tomography scan.

Sadece kayıtlı kullanıcılar makaleleri çevirebilir
Giriş yapmak kayıt olmak
Bağlantı panoya kaydedilir
Sabri Zincirkeser
Zeki Y Celen
Mustafa Yilmaz
Fadime Topalhan
Ertan Sahin

Anahtar kelimeler

Öz

We present a 42-year-old patient who was examined in the Gastroenterology Department of Gaziantep University for chronic abdominal pain, nausea and vomiting. Ultrasonography showed a 4.7 cm solid hepatic mass on the right lateral side of the right lobe of the liver. The patient was then sent to the Nuclear Medicine Department of Gaziantep University for liver scan. After injecting autologous red blood cells labeled with 740 MBq of technetium-99m ((99m)Tc-RBC), early and delayed anterior planar images of the liver showed no significant findings because of the right kidney shine through the liver. Two days later, after injecting again 740 MBq of (99m)Tc-RBC, we performed a single photon emission tomography (SPET) scan but still this scan was nondiagnostic even in the delayed images of the liver. Three days later, after the iv injection of 185 MBq of technetium-99m-sulphur colloid ((99m)Tc-SC), we observed in the delayed SPET images of the liver, a mismatch defect with decreased focal uptake of (99m)Tc-SC at 60 min while the uptake of (99m)Tc-RBC at the same area was normal or slightly increased. The patient was then operated due to bleeding in the abdominal cavity. A cavernous hemangioma was found, confirmed by histology. The absorbed dose from all three diagnostic scanning procedures was: 4 mSv. In conclusion, the mismatch of the SPET delayed images between the (99m)Tc-RBC and the (99m)Tc-SC scans indicated that this procedure was effective for the diagnosis of liver cavernous hemangioma located in this unusual position.

Facebook sayfamıza katılın

Bilim tarafından desteklenen en eksiksiz şifalı otlar veritabanı

  • 55 dilde çalışır
  • Bilim destekli bitkisel kürler
  • Görüntüye göre bitki tanıma
  • Etkileşimli GPS haritası - bölgedeki bitkileri etiketleyin (yakında)
  • Aramanızla ilgili bilimsel yayınları okuyun
  • Şifalı bitkileri etkilerine göre arayın
  • İlgi alanlarınızı düzenleyin ve haber araştırmaları, klinik denemeler ve patentlerle güncel kalın

Bir belirti veya hastalık yazın ve yardımcı olabilecek bitkiler hakkında bilgi edinin, bir bitki yazın ve karşı kullanıldığı hastalıkları ve semptomları görün.
* Tüm bilgiler yayınlanmış bilimsel araştırmalara dayanmaktadır

Google Play badgeApp Store badge