Ukrainian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Applied Physiology 1994-Feb

51Cr-RBCs and 125I-albumin as markers to estimate lymph drainage of the peritoneal cavity in sheep.

Тільки зареєстровані користувачі можуть перекладати статті
Увійти Зареєструватися
Посилання зберігається в буфері обміну
Z Y Yuan
H Rodela
J B Hay
D Oreopoulos
M G Johnston

Ключові слова

Анотація

The purpose of this study was to compare the use of 125I-labeled human serum albumin (125I-HSA) and autologous 51Cr-labeled red blood cells (51Cr-RBCs) as lymph flow markers to estimate lymph drainage of the peritoneal cavity in conscious sheep. In one group, we assessed lymph drainage from the appearance of intraperitoneally administered tracer in the bloodstream. To determine distribution of drainage into discrete lymph compartments, in a second group of studies, lymph was collected from the caudal mediastinal lymph node and the thoracic duct, both of which are involved in lymphatic drainage of the ovine peritoneal cavity. Ringer lactate solution (50 ml/kg) containing 8-10 microCi each of 125I-HSA and 51Cr-RBCs was infused into the peritoneal cavity. Lymph drainage was calculated by dividing the change in mass of tracer in the blood or lymph compartments by the average intraperitoneal tracer concentration. In noncannulated animals, lymph drainage averaged over 6 h was higher with 125I-HSA as tracer (1.35 +/- 0.12 vs. 0.62 +/- 0.19 ml.h-1.kg-1 with 51Cr-RBCs). A similar pattern was noted in terms of drainage into the caudal lymphatic (0.89 +/- 0.23 and 0.52 +/- 0.19 ml.h-1.kg-1 with 125I-HSA and 51Cr-RBCs, respectively) and thoracic duct (0.16 +/- 0.06 and 0.05 +/- 0.02 ml.h-1.kg-1 with 125I-HSA and 51Cr-RBCs, respectively). Analysis of 125I-HSA and 51Cr-RBC concentrations in lymph and intraperitoneal fluid suggested sieving of RBCs at the diaphragmatic stomata or lymph nodes. Using 125I-HSA as tracer and combining data from noncannulated and cannulated sheep, we estimated peritoneal lymph drainage to be 1.35 ml.h-1.kg-1, with 66% of this flow drained by the caudal vessel, 22% by the parasternal pathway (right lymph duct), and 12% by the thoracic duct.

Приєднуйтесь до нашої
сторінки у Facebook

Найповніша база даних про лікарські трави, підкріплена наукою

  • Працює 55 мовами
  • Лікування травами за підтримки науки
  • Розпізнавання трав за зображенням
  • Інтерактивна GPS-карта - позначайте трави на місці (скоро)
  • Читайте наукові публікації, пов’язані з вашим пошуком
  • Шукайте лікарські трави за їх впливом
  • Організуйте свої інтереси та будьте в курсі новинних досліджень, клінічних випробувань та патентів

Введіть симптом або хворобу та прочитайте про трави, які можуть допомогти, наберіть траву та ознайомтесь із захворюваннями та симптомами, проти яких вона застосовується.
* Вся інформація базується на опублікованих наукових дослідженнях

Google Play badgeApp Store badge