Ukrainian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2010-Jun

Comparison between evaporative light scattering detection and charged aerosol detection for the analysis of saikosaponins.

Тільки зареєстровані користувачі можуть перекладати статті
Увійти Зареєструватися
Посилання зберігається в буфері обміну
Han Young Eom
So-Young Park
Min Kyung Kim
Joon Hyuk Suh
Hyesun Yeom
Jung Won Min
Unyong Kim
Jeongmi Lee
Jeong-Rok Youm
Sang Beom Han

Ключові слова

Анотація

Saikosaponins are triterpene saponins derived from the roots of Bupleurum falcatum L. (Umbelliferae), which has been traditionally used to treat fever, inflammation, liver diseases, and nephritis. It is difficult to analyze saikosaponins using HPLC-UV due to the lack of chromophores. Therefore, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) method has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we compared CAD and ELSD methods in the simultaneous analysis of 10 saikosaponins, including saikosaponins-A, -B(1), -B(2), -B(3), -B(4), -C, -D, -G, -H and -I. A mixture of the 10 saikosaponins was injected into the Ascentis Express C18 column (100 mm x 4.6 mm, 2.7 microm) with gradient elution and detection with CAD and ELSD by splitting. We examined various factors that could affect the sensitivity of the detectors including various concentrations of additives, pH and flow rate of the mobile phase, purity of nitrogen gas and the CAD range. The sensitivity was determined based on the signal-to-noise ratio. The best sensitivity for CAD was achieved with 0.1 mM ammonium acetate at pH 4.0 in the mobile phase with a flow rate of 1.0 mL/min, and the CAD range at 100 pA, whereas that for ELSD was achieved with 0.01% acetic acid in the mobile phase with a flow rate at 0.8 mL/min. The purity of the nitrogen gas had only minor effects on the sensitivities of both detectors. Finally, the sensitivity for CAD was two to six times better than that of ELSD. Taken together, these results suggest that CAD provides a more sensitive analysis of the 10 saikosaponins than does ELSD.

Приєднуйтесь до нашої
сторінки у Facebook

Найповніша база даних про лікарські трави, підкріплена наукою

  • Працює 55 мовами
  • Лікування травами за підтримки науки
  • Розпізнавання трав за зображенням
  • Інтерактивна GPS-карта - позначайте трави на місці (скоро)
  • Читайте наукові публікації, пов’язані з вашим пошуком
  • Шукайте лікарські трави за їх впливом
  • Організуйте свої інтереси та будьте в курсі новинних досліджень, клінічних випробувань та патентів

Введіть симптом або хворобу та прочитайте про трави, які можуть допомогти, наберіть траву та ознайомтесь із захворюваннями та симптомами, проти яких вона застосовується.
* Вся інформація базується на опублікованих наукових дослідженнях

Google Play badgeApp Store badge