Ukrainian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Radiology 2013-Nov

Detection of myocardial edema with low-b-value diffusion-weighted echo-planar imaging sequence in patients with acute myocarditis.

Тільки зареєстровані користувачі можуть перекладати статті
Увійти Зареєструватися
Посилання зберігається в буфері обміну
Julien Potet
Alain Rahmouni
Julie Mayer
Alexandre Vignaud
Pascal Lim
Alain Luciani
Jean-Luc Dubois-Randé
Hicham Kobeiter
Jean-François Deux

Ключові слова

Анотація

OBJECTIVE

To evaluate the performance of a low-b-value diffusion-weighted (DW) echo-planar (EP) imaging sequence for detection of regional and diffuse myocardial edema in patients with acute myocarditis.

METHODS

This study was approved by the institutional review board, and informed consent was obtained from all subjects. Thirteen patients with acute myocarditis and a control group of seven healthy adults underwent low-b-value (50 sec/mm(2)) DW cardiac magnetic resonance imaging. DW EP images were acquired in the four-chamber long-axis section and analyzed qualitatively and quantitatively. Short inversion time inversion-recovery (STIR) T2-weighted and late gadolinium chelate enhancement images were acquired in the same plane and analyzed. Late gadolinium chelate enhancement was used as the reference standard. Statistical analyses were performed with a receiver operating characteristic analysis and a nonparametric Wilcoxon test.

RESULTS

Qualitative analysis showed myocardial high-signal-intensity areas in 100% (13 of 13) of patients on DW EP, 38% (five of 13) on STIR T2-weighted, and 100% (13 of 13) on late gadolinium chelate enhancement images. In eight patients (61%), high-signal-intensity areas were exhibited on DW EP images that were not detected on STIR T2-weighted images, but were colocalized with lesions detected on late gadolinium chelate enhancement images. Similar results were obtained by using an automatic analysis with dedicated cardiac software. The global myocardial signal intensity ratio was significantly higher (P = .03) in patients than in controls for DW EP (2.2 ± 0.4 [standard deviation] vs 1.1 ± 0.4, respectively), and exhibited no significant difference (P = .14) for STIR T2-weighted (1.7 ± 0.6 vs 1.4 ± 0.1, respectively) images. Sensitivity and diagnostic accuracy were higher for DW EP images than for STIR T2-weighted images (92% vs 54%, and 95% vs 70%, respectively), and specificity was the same (100% vs 100%).

CONCLUSIONS

A low-b-value DW EP imaging sequence is a feasible alternative to the standard STIR T2-weighted sequence for detection of regional and global myocardium edema in patients with acute myocarditis.

BACKGROUND

http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13121811/-/DC1.

Приєднуйтесь до нашої
сторінки у Facebook

Найповніша база даних про лікарські трави, підкріплена наукою

  • Працює 55 мовами
  • Лікування травами за підтримки науки
  • Розпізнавання трав за зображенням
  • Інтерактивна GPS-карта - позначайте трави на місці (скоро)
  • Читайте наукові публікації, пов’язані з вашим пошуком
  • Шукайте лікарські трави за їх впливом
  • Організуйте свої інтереси та будьте в курсі новинних досліджень, клінічних випробувань та патентів

Введіть симптом або хворобу та прочитайте про трави, які можуть допомогти, наберіть траву та ознайомтесь із захворюваннями та симптомами, проти яких вона застосовується.
* Вся інформація базується на опублікованих наукових дослідженнях

Google Play badgeApp Store badge