Ukrainian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Microbiology and Biotechnology 2016-Dec

Novel Approach of a Phage-Based Magnetoelastic Biosensor for the Detection of Salmonella enterica serovar Typhimurium in Soil.

Тільки зареєстровані користувачі можуть перекладати статті
Увійти Зареєструватися
Посилання зберігається в буфері обміну
Mi-Kyung Park
Bryan A Chin

Ключові слова

Анотація

To date, there has been no employment of a magnetoelastic (ME) biosensor method to detect Salmonella enterica serovar Typhimurium in soil. The ME biosensor method needs to be investigated and modified for its successful performance. The filtration method, cation-exchange resin method, and combinations of both methods were employed for the extraction of S. Typhimurium from soil. The number of S. Typhimurium and the resonant frequency shift of the ME sensor were then compared using a brilliant green sulfa agar plate and an HP 8751A network analyzer. A blocking study was performed using bovine serum albumin (BSA), polyethylene glycol (PEG), and casein powder suspension. Finally, the modified ME biosensor method was performed to detect S. Typhimurium in soil. The number of S. Typhimurium was significantly decreased from 7.10 log CFU/soil to 4.45-4.72 log CFU/soil after introduction of the cation-exchange resin method. The greatest resonant frequency shift of the measurement sensor was found when employing centrifugation and filtration procedures. The resonant frequency shift of the PEG-blocked measurement sensor was 3,219 ± 755 Hz, which was significantly greater than those of the BSA- and casein-blocked ME sensor. The optimum concentration of PEG was determined to be 1.0 mg/ml after considering the resonant shift and economic issue. Finally, the modified ME biosensor method was able to detect S. Typhimurium in soil in a dose-response manner. Although these modifications of the ME biosensor method sacrificed some advantages, such as cost, time effectiveness, and operator friendliness, this study demonstrated a novel approach of the ME biosensor method to detect S. Typhimurium in soil.

Приєднуйтесь до нашої
сторінки у Facebook

Найповніша база даних про лікарські трави, підкріплена наукою

  • Працює 55 мовами
  • Лікування травами за підтримки науки
  • Розпізнавання трав за зображенням
  • Інтерактивна GPS-карта - позначайте трави на місці (скоро)
  • Читайте наукові публікації, пов’язані з вашим пошуком
  • Шукайте лікарські трави за їх впливом
  • Організуйте свої інтереси та будьте в курсі новинних досліджень, клінічних випробувань та патентів

Введіть симптом або хворобу та прочитайте про трави, які можуть допомогти, наберіть траву та ознайомтесь із захворюваннями та симптомами, проти яких вона застосовується.
* Вся інформація базується на опублікованих наукових дослідженнях

Google Play badgeApp Store badge