Scandinavian Journal of Gastroenterology 1999-Nov

13C mixed-triglyceride breath test: isotope selective non-dispersive infrared spectrometry in comparison with isotope ratio mass spectrometry in volunteers and patients with chronic pancreatitis.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
C Boedeker
O Goetze
B Pfaffenbach
A Luypaerts
B Geypens
R J Adamek

Từ khóa

trừu tượng

BACKGROUND

The 13C mixed-triglyceride breath test (MTB) has been proposed for the non-invasive assessment of duodenal pancreatic lipase activity. Until now, stable isotope analysis of CO2 of the MTB has been carried out with isotope ratio mass spectrometry (IRMS). The aim of the present study was to compare MTB results by using the new non-dispersive infrared spectrometry (NDIRS) and the IRMS.

METHODS

Ten healthy volunteers and 10 patients with chronic pancreatitis and exocrine insufficiency were studied. After an overnight fast each subject received a test meal containing 250 mg 1,3 distearyl, 2[13C] octanoyl glycerol. Breath samples were taken at base line and at 30-min intervals over a period of 6 h postprandially. The 13C/12C ratio was determined in each breath sample by NDIRS and CF-IRMS as delta values. Results were expressed as delta over base line (DOB (per 1000)) and as cumulative percentage dose of 13C recovered (cPDR (%)). Correlations between IRMS and NDIRS were tested by linear regression analysis. For measuring agreement an Altman-Bland plot was performed.

RESULTS

A linear correlation was found (DOB: y = 0.645 +/- 0.040 x + 1.496 +/- 0.089, r = 0.70, P < 0.0001; cPDR: y = 1.269 +/- 0.031 x + 2.010 +/- 0.353, r = 0.93, P < 0.0001). For DOB the mean difference (d) was 1.0/1000, and the standard deviation (s) of the difference was 1.3/1000. The limits of agreement (d +/- 2 s) were -1.6/1000 and 3.6/1000.

CONCLUSIONS

The comparison of DOB and cPDR values by NDIRS and IRMS shows a moderate to good linear correlation. However, the distance of the limits of agreement is rather wide. Consequently, the validity of the MTB is diminished, which makes MTB by NDIRS less suitable for exact evaluation of non-invasive assessment of duodenal pancreatic lipase activity. Further studies are necessary to determine sensitivity and specificity of the MTB with NDIRS in larger study populations.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn