Vietnamese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Food Control 2017-Jul

Assessment of critical steps of a GC/MS based indirect analytical method for the determination of fatty acid esters of monochloropropanediols (MCPDEs) and of glycidol (GEs).

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
Zuzana Zelinkova
Anupam Giri
Thomas Wenzl

Từ khóa

trừu tượng

Fatty acid esters of 2- and 3-chloropropanediol (MCPDEs) and fatty acid esters of glycidol (GEs) are commonly monitored in edible fats and oils. A recommendation issued by the European Commission emphasizes the need of generating data on the occurrence of these substances in a broad range of different foods. So far, analytical methods for the determination of MCPDEs and GEs are fully validated only for oils, fats and margarine. This manuscript presents the assessment of critical steps in the AOCS Cd 29a-13 method for the simultaneous determination of MCPDEs and GEs in the fat phase obtained from bakery and potato products, smoked and fried fish and meat, and other cereal products. The trueness of the method is affected by the additional formation of 3-MBPD esters from monoacylglycerols (MAGs), which are frequently present in food. The overestimation of GE contents for some samples was confirmed by the comparison of results with results obtained by an independent analytical method (direct analysis of GE by HPLC-MS/MS). An additional sample pre-treatment by SPE was introduced to remove MAGs from fat prior to the GEs conversion, while the overall method sensitivity was not significantly affected. Trueness of the determination of GEs by the modified analytical procedure was confirmed by comparison with a direct analysis of GEs. The potential impact on accuracy of results of the final sample preparation step of the analytical procedure, the derivatization of free forms MCPD and MBPD with PBA, was evaluated as well. Different commercial batches of PBA showed differences in solubility in a non-polar organic solvent. The PBA derivatization in organic solvent did not affect precision and trueness of the method due to the isotopic standard dilution. However, method sensitivity might be significantly compromised.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge