Journal of Clinical Monitoring and Computing 2005-Apr

Cerebral monitoring in the operating room and the intensive care unit - an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part II: Sensory-evoked potentials (SSEP, AEP, VEP).

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
Enno Freye

Từ khóa

trừu tượng

An evoked potential differs from the EEG mainly in two ways: 1. The EEG is a random, continuous signal, which arises from the ongoing activity of the outer layers of the cortex. An evoked potential is the brain's response to a repetitive stimulus along a specific nerve pathway. 2.EEG signals range from 10-200 milliVolt (mV). Evoked potentials are smaller in amplitude (1-5-20 microVolt requiring precise electrode positioning and special techniques (signal averaging) to extract the specific response from the underlying EEG "noise". The technique of signal averaging, as originally described by Dawson in 1954 [69J, has been further developed in computer processing. The technique is now used by applying a stimulus repeatedly--preferably at randomized intervals--and to record the evoked response over the corresponding area of the brain, averaging out mathematically the change over the number of stimuli. Rationale for the use of EPs in the OR and the ICU. Evoked potentials (EPs) serve the following major purposes: 1. Monitoring of the functional integrity of neural structures that may be at risk during, for instance, ECC (extracorporeal circulation) or endarterectomy indicating cerebral hypoxia. 2. Monitoring of the effects of anesthetic agents and other centrally active drugs, which, besides the cortex, affect deeper neuronal structures. 3. Orthopedic cases where the spinal cord is at risk such as Harrington rod insertion and removal. 4. Clamping of the abdominal aortic artery during aneurysmectomy resulting in a potential damage of the lower parts of the spinal cord. 5. Clipping of an intracerebral aneurysm, which may be impeding blood flow to vital cerebral textures. 6. An indicator of cerebral hypoxia when the blood pressure is deliberately lowered. 7. Operation on peripheral nerves and nerve roots to identify early trauma. 8. Monitoring the cerebral function during controlled hypothermia when the EEG becomes flat. 9. Monitoring of the pathophysiological conditions after severe head trauma and the effects of therapy. 10. An intraoperative warning device of unsuspected awareness during light anesthesia when movement is abolished by muscle relaxants and cardiovascular responses are modified by vasoactive drugs. In case of the latter the stimulus is a small electrical potential applied to the skin of the hand. Thereafter, the stimulus travels along the specific nervous pathways inducing (= generating) potential activation at various sites. The generation of potential changes at various sites along the pathway is an index for the integrity of the nerve. Thus, the evoked potential can be considered a neurophysiological response (usually of the cortex) to impulses originating from some externally stimulated sensory nerve. They provide a physiological measure of the functional integrity of the sensory nerve pathway, which can be used as a clinical diagnostic tool as well as for intraoperative monitoring. The evoked potential usually is recorded from the specific cortical area corresponding to the stimulus input. The classification of evoked potentials. Stimulating a sensory nervous pathway induces evoked potentials. If the auditory nerve is stimulated by "clicks" from headphones, it is called the auditory evoked potential (AEP). The early part of the AEP waveform (less than 10 msec) is called the Brainstem Auditory Evoked Potential (BAEP) since it reflects the passing of the impulse through the brainstem. If a nerve on the arm or the leg is stimulated by a small electrical current applied to the overlying skin, it is called the Somatosensory Evoked Potential (SSEP). If, however, the retina is stimulated by means of flicker light or a sudden change in a checkerboard pattern, the evoked potential thus recorded over the corresponding cortical area is called the Visual Evoked Potential (VEP). Evoked potentials are used both as a diagnostic tool and as a monitoring technique. As diagnostic tests, evoked potentials are useful to evaluate neurologic disorders such as: a) multiple sclerosis, b) acoustic nerve tumors, and c) optic neuritis. As a monitoring modality, evoked potentials are used during all surgical procedures, which might compromise part of the brain or the spinal cord.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge