The Journal of trauma 2000-Mar

Comparison of poly-N-acetyl glucosamine (P-GlcNAc) with absorbable collagen (Actifoam), and fibrin sealant (Bolheal) for achieving hemostasis in a swine model of splenic hemorrhage.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
M W Chan
S D Schwaitzberg
M Demcheva
J Vournakis
S Finkielsztein
R J Connolly

Từ khóa

trừu tượng

OBJECTIVE

To compare the hemostatic capabilities of poly-Nacetylglucosamine (p-GlcNAc) with three currently available products: Actifoam, Surgicel, and Bolheal fibrin glue. This study was conducted in a controlled animal model, with monitoring of hematologic parameters over the course of the study. Two series were conducted, one in unheparinized animals comparing Bolheal fibrin sealant, Actifoam (absorbable collagen, AC), and Surgicel (ORC) with p-GlcNAc, and the second in systemically heparinized animals comparing p-GlcNAc with AC.

METHODS

This study was performed in immature female Yorkshire White swine. Splenic lacerations controlled for length and depth of wound were used as sources of bleeding, with one material used per wound to assess hemostatic effectiveness. A total of 97 wounds in 12 animals were created for the study, 74 wounds in unheparinized animals, and 23 wounds in the heparinized animals. In the heparinized animals, hemostatic efficacy was judged by number of applications needed to achieve complete hemostasis. In the unheparinized animals, hemostatic efficacy was judged by length of time required to achieve complete hemostasis (p-GlcNAc vs. fibrin sealant) or the number of applications needed to achieve complete hemostasis (p-GlcNAc vs. AC or ORC).

RESULTS

In systemically heparinized animals, p-GlcNAc demonstrated greater hemostatic efficacy (72.7 %) in one application than did the control material (0%), p < 0.01. In the unheparinized animals, p-GlcNAc took less time to achieve hemostasis (mean, 22.9 seconds) than fibrin sealant (mean, 172.9 seconds), p < 0.01. p-GlcNAc achieved hemostasis with a greater efficacy (79.2%) in one application than did the AC or ORC (16.7%), p < 0.01, whereas there was no difference in the efficacy of the control materials.

CONCLUSIONS

The results of the previous series in unheparinized animals demonstrated that p-GlcNAc in the form of a membrane is a more effective topical hemostatic agent than Bolheal fibrin glue, AC or ORC. The results in the anticoagulated animals similarly demonstrate that p-GlcNAc is a more effective topical hemostatic agent than the control material AC. These data indicate that p-GlcNAc is a promising hemostatic agent as evaluated in this model.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge