BMC Pulmonary Medicine 2009-Dec

Effects of acute hypoventilation and hyperventilation on exhaled carbon monoxide measurement in healthy volunteers.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
Franco Cavaliere
Carmen Volpe
Riccardo Gargaruti
Andrea Poscia
Michele Di Donato
Giovanni Grieco
Umberto Moscato

Từ khóa

trừu tượng

BACKGROUND

High levels of exhaled carbon monoxide (eCO) are a marker of airway or lung inflammation. We investigated whether hypo- or hyperventilation can affect measured values.

METHODS

Ten healthy volunteers were trained to achieve sustained end-tidal CO2 (etCO(2)) concentrations of 30 (hyperventilation), 40 (normoventilation), and 50 mmHg (hypoventilation). As soon as target etCO(2) values were achieved for 120 sec, exhaled breath was analyzed for eCO with a photoacoustic spectrometer. At etCO(2) values of 30 and 40 mmHg exhaled breath was sampled both after a deep inspiration and after a normal one. All measurements were performed in two different environmental conditions: A) ambient CO concentration = 0.8 ppm and B) ambient CO concentration = 1.7 ppm.

RESULTS

During normoventilation, eCO mean (standard deviation) was 11.5 (0.8) ppm; it decreased to 10.3 (0.8) ppm during hyperventilation (p < 0.01) and increased to 11.9 (0.8) ppm during hypoventilation (p < 0.01). eCO changes were less pronounced than the correspondent etCO(2) changes (hyperventilation: 10% Vs 25% decrease; hypoventilation 3% Vs 25% increase). Taking a deep inspiration before breath sampling was associated with lower eCO values (p < 0.01), while environmental CO levels did not affect eCO measurement.

CONCLUSIONS

eCO measurements should not be performed during marked acute hyperventilation, like that induced in this study, but the influence of less pronounced hyperventilation or of hypoventilation is probably negligible in clinical practice.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge