Vietnamese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Clinical Oral Investigations 1999-Mar

Fatigue behaviour of different dentin adhesives.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
R Frankenberger
N Krämer
A Petschelt

Từ khóa

trừu tượng

The aim of this in vitro study was to compare quasistatic and cyclic fatigue dentin bond strength of modern adhesive systems representing different generations. One hundred and fifty cavities were made in discs of freshly extracted human third molars and filled with direct resin composite restorations. Dentin adhesives of different generations (SY = Syntac Classic, multi-step system with self-etching primer; SE = Syntac Classic with additional phosphoric acid etching prior to application of the self-etching primer; SB = Scotchbond Multi-Purpose Plus, multi-step system with total etching; PE = Prime & Bond 2.1, single-step system with and without [PB] total etching) were used in combination with one hybrid composite. After 21 days of storage, 10 specimens for each adhesive system were subjected to thermocycling (1150 cycles) for 24 h and were afterwards debonded in a push-out test. Another 20 specimens were tested with cyclic fatigue according to the staircase method with 5000 cycles for each specimen. Static and cyclic push-out bond strengths, respectively, for each group were (MPa): SY 16.9 +/- 0.9 and 14.2 +/- 1.7, SE 17.5 +/- 1.8 and 14.8 +/- 3.4, SB 18.5 +/- 1.7 and 13.9 +/- 2.1, PB 14.6 +/- 2.2 and 7.2 +/- 2.4, PE 13.4 +/- 2.2 and 6.8 +/- 1.8. Both quasistatic and dynamic bond strengths revealed better values for the multi-step systems (P < 0.05). All adhesive systems tested revealed a significant fatigue behaviour which was more pronounced for the one-bottle system with a decrease of about 50% independent of additional dentin etching.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge