Vietnamese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of the American College of Cardiology 1994-Oct

How accurate is dobutamine stress electrocardiography for detection of coronary artery disease? Comparison with two-dimensional echocardiography and technetium-99m methoxyl isobutyl isonitrile (mibi) perfusion scintigraphy.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
G H Mairesse
T H Marwick
J L Vanoverschelde
T Baudhuin
W Wijns
J A Melin
J M Detry

Từ khóa

trừu tượng

OBJECTIVE

This study was designed to establish the appropriate diagnostic criteria for positive dobutamine electrocardiographic (ECG) stress test results and to compare their accuracy with those of dobutamine two-dimensional echocardiography and perfusion scintigraphy.

BACKGROUND

Conventional criteria for positive findings on ECG exercise testing may not be appropriate for use with dobutamine ECG stress testing.

METHODS

One hundred twenty-nine consecutive patients with an interpretable ECG and without previous myocardial infarction were prospectively studied at the time of coronary arteriography. All completed a standard dobutamine protocol (5 to 40 micrograms/kg body weight per min in 3-min dose increments) without side effects. Significant coronary artery disease, defined as > 50% lumen diameter stenosis of a major epicardial coronary artery on coronary angiography, was present in 83 patients. Empiric receiver operating curves were generated for various ECG criteria derived from computer-averaged signals.

RESULTS

The best ECG criterion, with a sensitivity of 42% and a specificity of 83%, was an ST segment shift, relative to baseline, of 0.5 mm 80 ms after the J point. The sensitivity of this criterion was greater than that of the conventional criterion of 1-mm ST segment depression 60 (23%) or 80 (18%) ms after the J point, was comparable to that of chest pain occurring during the test (44%, p = NS) but remained inferior to the sensitivities of technetium-99m methoxyl isobutyl isonitrile (mibi) perfusion (76%) or stress echocardiography (76%, p < 0.001, for both). The specificity of this criterion was not significantly different from that of technetium-99m mibi perfusion tomography (65%) or stress echocardiography (89%) but was superior to that of chest pain (59%, p < 0.025).

CONCLUSIONS

We conclude that this new criterion for dobutamine electrocardiography is specific but that an imaging technique is still required to accurately predict coronary artery disease.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge