Vietnamese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Free Radical Research 1998-Jan

Nasal cavity lining fluid ascorbic acid concentration increases in healthy human volunteers following short term exposure to diesel exhaust.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
A Blomberg
C Sainsbury
B Rudell
A J Frew
S T Holgate
T Sandström
F J Kelly

Từ khóa

trừu tượng

To determine if diesel exhaust (DE) exposure modifies the antioxidant defense network within the respiratory tract lining fluids, a randomized, single blinded, crossover control study using nasal lavage and flexible video bronchoscopy with bronchial and bronchoalveolar lavage was performed. Fifteen healthy, non-smoking, asymptomatic subjects were exposed to filtered air or diluted diesel exhaust (300mg m(-3) particulates, 1.6ppm nitrogen dioxide) for one hour on 2 separate occasions, at least three weeks apart. To examine the kinetics of any DE-induced antioxidant reactions, nasal lavage fluid and blood samples were collected prior to, immediately after, and 5 1/2 hours post exposure. Bronchoscopy was performed 6 hours after the end of DE exposure. Ascorbic acid, uric acid and reduced glutathione (GSH) concentrations were determined in nasal, bronchial, bronchoalveolar lavage and plasma samples. Malondialdehyde (MDA) and protein carbonyl concentrations were determined in plasma and bronchoalveolar lavage samples. Nasal lavage ascorbic acid concentration increased 10-fold during DE exposure [1.02 (0.26-2.09) Vs 7.13 (4.66-10.79) micromol/L(-1)], but returned to basal levels 5.5 hours post-exposure [0.75 (0.26-1.51) micromol/L(-1)]. There was no significant effect of DE exposure on nasal lavage uric acid or GSH concentration. DE exposure did not influence plasma, bronchial wash, or bronchoalveolar lavage antioxidant concentrations and no change in MDA or protein carbonyl concentrations were found. The physiological response to acute DE exposure is an increase in the level of ascorbic acid in the nasal cavity. This response appears to be sufficient to prevent further oxidant stress in the respiratory tract of normal individuals.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge