Vietnamese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Cardiology 1995-Nov

Normal stroke volume and cardiac output response during dobutamine stress echocardiography in subjects without left ventricular wall motion abnormalities.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
P A Pellikka
V L Roger
R B McCully
D W Mahoney
K R Bailey
J B Seward
A J Tajik

Từ khóa

trừu tượng

Dobutamine stress echocardiography has become widely utilized for evaluation of coronary artery disease, but the expected responses of stroke volume and cardiac output to the high doses of dobutamine administered in these studies are not known. To determine these responses, stroke volume and cardiac output were measured with 2-dimensional Doppler echocardiography at each stage of dobutamine stress echocardiography and after administration of atropine in 47 patients without resting or inducible wall motion abnormalities. Heart rate increased significantly at each stage of dobutamine infusion and after atropine. Mean blood pressure decreased at the 5 micrograms/kg/min dose, then showed little change. Stroke volume increased 27 +/- 18% from baseline, with significant increases occurring at both the 5 and 10 micrograms/kg/min doses (p < 0.00001). With higher doses of dobutamine, stroke volume tended to plateau or decrease. Mean changes in stroke volume were not significant between the doses of 10, 20, and 30 micrograms/kg/min. The mean change in stroke volume from the 30 to the 40 micrograms/kg/min dose was a significant decrease of 6.3% (p = 0.004); the decrease from the 40 micrograms/kg/min dose to atropine approached statistical significance (p = 0.06). Cardiac output increased throughout dobutamine infusion. Stroke volume during dobutamine stress echocardiography is commonly maximum at a dose of 20 micrograms/kg/min and tends to decline at higher infusion rates. At higher doses, increases in cardiac output are mediated primarily by increases in heart rate.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge