Vietnamese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
European Spine Journal 2019-Oct

The most appropriate cervical vertebra for the measurement of occipitocervical inclination parameter: a validation study of C3, C4, and C5 levels using multi-positional magnetic resonance imaging.

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
Permsak Paholpak
Blake Formanek
Andrew Vega
Koji Tamai
Zorica Buser
Jeffrey Wang

Từ khóa

trừu tượng

To evaluate which cervical level is the most appropriate level to measure occipitocervical inclination (OCI).Sixty-two patients with multi-positional MRI: 24 males and 38 females, who had cervical lordosis and had a disk degeneration grade of 3 or less were included. We measured patient's OCI at C3, C4, and C5, occipitocervical angle (OCA), occipitocervical distance (OCD), C2-7 angle, and cervical sagittal vertical axis (cSVA) in neutral, flexion, and extension position. The correlation between OCI and OCA, OCD, C2-7 angle, and cSVA on each cervical level in all three positions was tested using Pearson's correlation coefficient test. The difference between OCIs at each cervical level was tested by Wilcoxon signed-rank test. p value of less than 0.05 was set as a statistically significant level.C5 OCI showed statistically significant correlation with OCA, OCD, C2-7 angle, and cSVA in all three positions (p < 0.05, r = 0.214-0.525). C3 OCI in flexion (p = 0.393, r = 0.081) and C4 OCI in neutral and flexion (neutral p = 0.275, r 0.104; flexion p = 0.987, r = 0.002) did not show significant correlation with C2-7 angle. There was a statistically significant difference between C3, C4, and C5 OCIs in neutral and extension position (p < 0.05). At the same time, OCI showed statistically strong correlation between adjacent cervical levels (p < 0.001, r = 0.627-0.822).C5 cervical level is the most appropriate level for OCI measurement. OCI should be measured at the same cervical level at all time. C4 OCI can reliably substitute C5 OCI in case C5 which is invisible on radiographic image. These slides can be retrieved under Electronic Supplementary Material.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge