Vietnamese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Methods 2020-Aug

A banana peel/silicon glue coated stir bar for extraction of aspirin, diclofenac, ibuprofen and mefenamic acid followed by high performance liquid chromatography-UV detection

Chỉ người dùng đã đăng ký mới có thể dịch các bài báo
Đăng nhập Đăng ký
Liên kết được lưu vào khay nhớ tạm
Zahra Jafari
Mohammad Hadjmohammadi

Từ khóa

trừu tượng

In the current study, a green, cost-effective, and bio-degradable additive was used for the preparation of a highly efficient sorbent based on silicon glue. Here, a banana peel was pretreated and mixed with silicon glue. It was proved that the prepared banana peel-silicon glue bar is a reliable sorbent for stir bar sorptive extraction of nonsteroidal anti-inflammatory drugs (NSAIDs) including aspirin, diclofenac, ibuprofen and mefenamic acid in human urine and plasma. Compared to the lab-made sorbents, the prepared sorbent showed high extraction performance, high stability, and satisfactory reproducibility and involved easy preparation. In order to optimize the effective factors, different parameters such as (stirring rate, pH, extraction time, desorption time and elution solvent volume) were optimized using response surface methodology (RSM) through applying Central-Composite Design (CCD). Under the optimum conditions, the linear dynamic ranges of the target analytes were investigated in the range of 0.2-200 μg L-1 with r2 higher than 0.9929. Limits of detection (LODs) and limits of quantification (LOQs) of analytes were in the ranges of 0.04-0.5 and 0.15-1.65, respectively. The reproducibility of the method was also investigated by calculating the relative standard deviation. The RSD was measured to be lower than 4.9%. Bar-to-bar reproducibility at a 100 μg L-1 concentration level was also evaluated to be lower than 5.3% (n = 3). Also, each prepared film can be used up to 64 times without any reduction in extraction performance. Finally, the method was successfully applied for the determination of selected drugs in different biological fluids including urine and plasma samples. The calculated relative recovery in real sample analysis was higher than 90%.

Tham gia trang
facebook của chúng tôi

Cơ sở dữ liệu đầy đủ nhất về dược liệu được hỗ trợ bởi khoa học

  • Hoạt động bằng 55 ngôn ngữ
  • Phương pháp chữa bệnh bằng thảo dược được hỗ trợ bởi khoa học
  • Nhận dạng các loại thảo mộc bằng hình ảnh
  • Bản đồ GPS tương tác - gắn thẻ các loại thảo mộc vào vị trí (sắp ra mắt)
  • Đọc các ấn phẩm khoa học liên quan đến tìm kiếm của bạn
  • Tìm kiếm dược liệu theo tác dụng của chúng
  • Sắp xếp sở thích của bạn và cập nhật các nghiên cứu tin tức, thử nghiệm lâm sàng và bằng sáng chế

Nhập một triệu chứng hoặc một căn bệnh và đọc về các loại thảo mộc có thể hữu ích, nhập một loại thảo mộc và xem các bệnh và triệu chứng mà nó được sử dụng để chống lại.
* Tất cả thông tin dựa trên nghiên cứu khoa học đã được công bố

Google Play badgeApp Store badge