Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Pediatric Surgery 2003-Oct

Clinical significance of 99mTc-DTPA-galactosyl human serum albumin liver scintigraphy in follow-up patients with biliary atresia.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Tomohiro Ishii
Masaki Nio
Satoru Shimaoka
Nobuyuki Sano
Hideyuki Sasaki
Dai Kimura
Yutaka Hayashi
Ryoji Ohi

الكلمات الدالة

نبذة مختصرة

OBJECTIVE

Technetium 99m DTPA-galactosyl human serum albumin (GSA) liver scintigraphy was performed in follow-up patients with biliary atresia, and its clinical significance was investigated.

METHODS

Between 1994 and 2001, GSA liver scintigraphy was performed 153 times in 57 follow-up patients. HH15, LHL15, and H/L15 (HH15/LHL15) were obtained. Patients were divided into 3 groups according to the clinical status (good, n = 17; fair, n = 24; poor, n = 16). The correlation between these parameters and liver function tests was examined. Twenty-six patients of the 57 underwent 3 serial GSA scintigraphies and also were divided into 3 groups (good, n = 13; fair, n = 8; poor, n = 5). (3rd/1st)H/L15 (3rd H/L15/1st H/L15) was obtained and compared.

RESULTS

H/L15 had a correlation with serum albumin and serum cholinesterase. H/L15 was statistically different among 3 groups (good, 0.97 +/- 0.15; fair, 0.94 +/- 0.09; poor, 1.12 +/- 0.21; P <.05). Although most patients in the good (10 patients; 76.9%) and fair (7 patients; 87.5%) groups showed (3rd/1st)H/L15 of less than 1.1, 3 patients (60%) in the poor group showed (3rd/1st)H/L15 of more than 1.1. (3rd/1st)H/L15 in the poor group was significantly higher than those in good and fair groups (P <.05).

CONCLUSIONS

Technetium 99m-GSA liver scintigraphy is useful to assess the functional hepatic reserve in follow-up patients with biliary atresia. Serial assessment with GSA scintigraphy can provide the trend of the patient's liver condition and can estimate the prognosis of the liver.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge