Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Techniques in urology 1997

Laser soldering technique for sutureless urethral surgery.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
A J Kirsch
D A Canning
S A Zderic
T W Hensle
J W Duckett

الكلمات الدالة

نبذة مختصرة

Investigators have attempted sutureless surgery to decrease operative time, lessen the inflammatory response, maintain luminal continuity, and increase the ease of performing technically difficult surgery. Only recently has laser-tissue welding (LTW) been used for urologic reconstruction in humans. Herein, we present our technique of laser soldering with the half-watt diode laser and wavelength matched albumin-based solder. Our methodology of LTW relies on bonding between the outer surface of the wound edges and the solder. The 808-nm diode wavelength does not penetrate deep tissue, and thus relies on indocyanine green dye to localize photon absorption. Since 1994, we have performed LTW, as an adjunct to suturing (N = 25) and as a primary means of tissue closure (N = 11). Preoperative diagnoses included hypospadias, urethral stricture, urethral diverticulum, and urethral fistulae. Follow-up ranged between 3 months and 3 years to identify complications of wound healing, stricture, and fistula formation. In the 37 patients undergoing urethral surgery, no strictures or diverticula have resulted. None of the patients have had wound infections or poor wound healing. Overall, five patients have developed fistulas between 2 weeks and 6 months postoperatively. The location of the hypospadiac meatus was scrotal or penoscrotal in four of these patients. Two fistulas developed following sutureless urethroplasty (reoperative) after traumatic catheterization for urinary retention (one case for inadvertent catheter removal). In our initial experience, the overall complication rate using laser soldering was 19% compared to 24% in an historical control group. Half of the complications occurred in a reoperative situation. More recently, the overall fistula rate was 14%; however, for primary cases, the current fistula rate is only 6%. LTW is safe and easy to perform. The application of protein solders (+/-chromophores) have permitted far greater tensile strengths to be achieved than laser alone. Temperature-control and chromophore-control have permitted safety and efficacy to be achieved. Solder application site and technique are equally important in the success of the LTW process. A randomized, prospective study comparing LTW to suturing is ongoing.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge