Thorax 1992-Oct

Quantification of right to left shunt at rest and during exercise in patients with pulmonary arteriovenous malformations.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
M K Whyte
A M Peters
J M Hughes
B L Henderson
G J Bellingan
J E Jackson
E R Chilvers

الكلمات الدالة

نبذة مختصرة

BACKGROUND

Current treatment of patients with pulmonary arteriovenous malformations requires serial embolisations by means of steel coils or balloons. Measurement of right to left shunt is the most specific index of response to treatment. A new method of measuring shunt has been developed that is less invasive than traditional methods.

METHODS

Right to left pulmonary shunt (expressed as percentage of cardiac output) was measured at rest in 19 patients with pulmonary arteriovenous malformations and six normal subjects by using intravenously injected albumin microspheres labelled with technetium-99m. The technique was compared with a simultaneous shunt measurement in subjects breathing 100% oxygen while they rested. The microsphere technique was adapted to measure the right to left shunt during exercise in 12 patients and five normal subjects with a new method of quantification.

RESULTS

The mean (SD) shunt at rest as measured by the microsphere method was 23.2% (15.6%) in the patients and 2.7% (1.2%) in the normal subjects. When these values were compared with those of the 100% oxygen method the difference in mean values was 1% and the limits of agreement between the two methods -32% to +45%. The microsphere method is less invasive (arterial blood gas sampling is not required), quicker, and more comfortable for patients than the 100% oxygen method. In five of the normal subjects the mean (SD) 99mTc microsphere shunt increased from 2.9% (1.3%) at rest to 5.1% (2.9%) during exercise. In the 12 patients studied during exercise the shunt increased from 33.7% (12.7%) at rest to 41.7% (13.3%) during exercise in eight but decreased from 22.6% (2.4%) at rest to 17.6% (2.2%) during exercise in four. Arterial desaturation during exercise correlated with change in the size of the right to left shunt during exercise (r = +0.80).

CONCLUSIONS

The microsphere method allows measurement of right to left shunt at rest and during exercise. Serial measurements at rest provide a simple, safe assessment of the physiological response to embolisation in patients with pulmonary arteriovenous malformations.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge