Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
European journal of nuclear medicine 1992

Scintigraphic evaluation of disease activity in rheumatoid arthritis: a comparison of technetium-99m human non-specific immunoglobulins, leucocytes and albumin nanocolloids.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
M Liberatore
M Clemente
A P Iurilli
L Zorzin
M Marini
E Di Rocco
A C Colella

الكلمات الدالة

نبذة مختصرة

Technetium-99m-labelled, non-specific, polyclonal, human immunoglobulin G (99mTc-hIG) has been used to quantify synovial inflammation in rheumatoid arthritis. A comparison was carried out between the scintigraphic results obtained with this tracer, 99mTc-hexamethylpropylene amine oxime-labelled white blood cells (99mTc-WBC) and 99mTc-albumin nanocolloids (99mTc-NC). Twenty patients affected by rheumatoid arthritis and suffering from clinically active synovitis were studied with 99mTc-hIG. The number and sites of the involved joints had been previously assessed on the basis of the presence of pain and/or swelling. A radiological examination had already been carried out on all the joints. Two days after the 99mTc-hIG scan, 10 patients (group 1) underwent 99mTc-WBC scintigraphy and the other 10 (group 2) underwent a 99mTc-NC scan. The results show that the results of 99mTc-hIG and 99mTc-NC scans are in agreement with clinical examinations in the majority of cases. However, a certain number of positive joint scans corresponding to negative clinical examinations was found. The numerical distribution of these results according to the radiological stages seems to show that 99mTc-hIG is more useful than 99mTc-NC in the initial phases of the disease. The 99mTc-WBC scan was negative in a consistent percentage of the joints previously assessed as clinically and 99mTc-hIG scan positive.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge