Plastic and Reconstructive Surgery - Global Open 2017-Jun

Tc-99m-Human Serum Albumin Transit Time as a Measure of Arm Breast Cancer-Related Lymphedema.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Navid M Toyserkani
Svend Hvidsten
Siavosh Tabatabaeifar
Jane A Simonsen
Poul F Høilund-Carlsen
Jens A Sørensen

الكلمات الدالة

نبذة مختصرة

BACKGROUND

Lymphoscintigraphy has often been used for evaluating arm lymphatic dysfunction, but no optimal approach for quantification has so far emerged. We propose a quantifiable measure of lymphatic function that we applied in patients treated for breast cancer.

METHODS

Eleven patients, aged 34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent bilateral lymphoscintigraphy using intradermal injection in both hands of technetium-99m-labeled human serum albumin and sequential 5 min imaging for 5 hours. The mean transit time (MTT) in the arms was calculated based on time activity curves generated from injection site and arm regions. Visual lymphedema scoring was performed based on dermal backflow and lymph node presence. Excess arm volume was calculated from circumference measurements.

RESULTS

The MTT (mean ± SD) was significantly longer in the lymphedema arm than in the normal arm: 60.1 ± 27.7 versus 5.4 ± 2.5 minutes (mean difference, 54.7 minutes; 95% confidence interval, 36.5-72.9 minutes; P < 0.0001). Patients with previous erysipelas infection had significantly longer MTT than other patients (mean difference, 43.7 minutes; 95% confidence interval, 18.6-68.7 minutes; P < 0.001). There was a positive correlation between MTT and excess arm volume (r = 0.64; P = 0.04) and number of lymph nodes removed (r = 0.65; P = 0.03) but no correlation between visual score and MTT.

CONCLUSIONS

Measurements of MTT were able to discriminate lymphedema from healthy arm and MTT correlated with relevant markers for lymphedema severity. We encourage further research using the MTT approach for monitoring lymphedema and evaluation of treatment response.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge