Clinical Physiology and Functional Imaging 2012-Mar

The washout rate of a subcutaneous 99mTc-HSA depot in lower extremity lymphoedema.

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
Mads R Jensen
Lene Simonsen
Tonny Karlsmark
Jens Bülow

Mots clés

Abstrait

OBJECTIVE

Lymphoscintigraphy is currently the leading diagnostic modality of lower extremity lymphoedema but has been criticized for being unreliable. Washout rate constants have been investigated and proven to be of diagnostic value in several studies of breast-cancer-related lymphoedema; however, the applicability in lower extremity lymphoedema needs further evaluation. The aim of the study was to verify if washout of (99m) Tc-human serum albumin ((99m) Tc-HSA) is a reliable diagnostic tool in lower extremity lymphoedema.

METHODS

Twenty healthy volunteers and eight patients (11 legs) with lymphoscintigraphy verified lower extremity lymphoedema participated in the study. A depot consisting of 0.1 ml 10 MBq/ml (99m) Tc-HSA was injected subcutaneously into the dorsum of each foot. The depot washout rate was measured using a portable scintillation detector system and time-activity curves were generated. After 30 min of supine rest and 10 min of standardized ergometric exercise, measurements were recorded for 20 min. Following correction for physical decay of (99m) Tc, the depot washout rate constant was calculated using linear regression analysis. Finally depot half-life was calculated from the washout rate constant.

RESULTS

Median half-life for healthy volunteers was 9.4 h (range 2.5-28.3 h). Median half-life for lymphoedema patients was 10.7 h (range 1.5-35.1 h). No statistical significant difference could be detected between healthy volunteers and lymphoedema patients (P = 0.78).

CONCLUSIONS

The washout rate of a subcutaneous (99m) Tc-HSA depot is not a reliable diagnostic tool in examination of lower extremity lymphoedema. Additional examinations revealed in vivo instability of the utilized (99m) Tc-HSA as the likely reason.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge