Italian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2012-Mar

Automated and quantitative headspace in-tube extraction for the accurate determination of highly volatile compounds from wines and beers.

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
Julián Zapata
Laura Mateo-Vivaracho
Ricardo Lopez
Vicente Ferreira

Parole chiave

Astratto

An automatic headspace in-tube extraction (ITEX) method for the accurate determination of acetaldehyde, ethyl acetate, diacetyl and other volatile compounds from wine and beer has been developed and validated. Method accuracy is based on the nearly quantitative transference of volatile compounds from the sample to the ITEX trap. For achieving that goal most methodological aspects and parameters have been carefully examined. The vial and sample sizes and the trapping materials were found to be critical due to the pernicious saturation effects of ethanol. Small 2 mL vials containing very small amounts of sample (20 μL of 1:10 diluted sample) and a trap filled with 22 mg of Bond Elut ENV resins could guarantee a complete trapping of sample vapors. The complete extraction requires 100 × 0.5 mL pumping strokes at 60 °C and takes 24 min. Analytes are further desorbed at 240 °C into the GC injector under a 1:5 split ratio. The proportion of analytes finally transferred to the trap ranged from 85 to 99%. The validation of the method showed satisfactory figures of merit. Determination coefficients were better than 0.995 in all cases and good repeatability was also obtained (better than 7% in all cases). Reproducibility was better than 8.3% except for acetaldehyde (13.1%). Detection limits were below the odor detection thresholds of these target compounds in wine and beer and well below the normal ranges of occurrence. Recoveries were not significantly different to 100%, except in the case of acetaldehyde. In such a case it could be determined that the method is not able to break some of the adducts that this compound forms with sulfites. However, such problem was avoided after incubating the sample with glyoxal. The method can constitute a general and reliable alternative for the analysis of very volatile compounds in other difficult matrixes.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca
  • Cerca le erbe medicinali in base ai loro effetti
  • Organizza i tuoi interessi e tieniti aggiornato sulle notizie di ricerca, sperimentazioni cliniche e brevetti

Digita un sintomo o una malattia e leggi le erbe che potrebbero aiutare, digita un'erba e osserva le malattie ei sintomi contro cui è usata.
* Tutte le informazioni si basano su ricerche scientifiche pubblicate

Google Play badgeApp Store badge