Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Biosensors and Bioelectronics 2017-Aug

Fabrication of nitrogen-doped carbon dots for screening the purine metabolic disorder in human fluids.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
N S K Gowthaman
Bharathi Sinduja
Rangasamy Karthikeyan
K Rubini
S Abraham John

キーワード

概要

Fabrication of nitrogen-doped carbon dots (N-CDs) electrode for the screening of purine metabolic disorder was described in this paper. Peroxynitrite is a short-lived oxidant species that is a potent inducer of cell death. Uric acid (UA) can scavenge the peroxynitrite to avoid the formation of nitrotyrosine, which is formed from the reaction between peroxynitrite and tyrosine (Try). Scavenging the peroxynitrite avoids the inactivation of cellular enzymes and modification of the cytoskeleton. Reduced level of UA decreases the ability of the body from preventing the peroxynitrite toxicity. On the other hand, the abnormal level of UA leads to gout and hyperuricemia. Allopurinol (AP) is administered in UA lowering therapy. Thus, the simultaneous determination of UA, Try and AP using N-CDs modified glassy carbon (GC) electrode was demonstrated for the first time. Initially, N-CDs were prepared from L-asparagine by pyrolysis and characterized by different spectroscopic and microscopic techniques. The HR-TEM image shows that the average size of the prepared N-CDs was 1.8±0.03nm. Further, the N-CDs were directly attached on GC electrode by simple immersion, follows Micheal's nucleophilic addition. XPS of N-CDs shows a peak at 285.3eV corresponds to the formation of C-N bond. The GC/N-CDs electrode shows higher electrocatalytic activity towards UA, Tyr and AP by not only shifting their oxidation potentials toward less positive potential but also enhanced their oxidation currents in contrast to bare GC electrode. The GC/N-CDs electrode shows the limit of detection of 13×10-10M (S/N=3) and the sensitivity of 924μAmM-1cm-2 towards the determination of UA. Finally, the N-CDs modified electrode was utilized for the determination of UA, Tyr and AP in human blood serum and urine samples.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge