Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Postepy w Kardiologii Interwencyjnej 2013

Large coronary artery fistula and patent ductus arteriosus: transcatheter closure with three PDA nitinol wire mesh occluders.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Jacek Bialkowski
Malgorzata Szkutnik
Gejung Zhang
Shilinag Jiang

キーワード

概要

Coronary artery fistulas (CAF) are the most common congenital anomaly of this vessel. We present the case of a 26-year-old man with two coexisting congenital cardiac defects: patent ductus arteriosus (PDA) and CAF. The patient 3 months earlier had the transcatheter PDA closed (type A, diameter 4 mm) with a 10/8 mm PDA nitinol wire mesh occluder. After the procedure he continued to have symptoms of fatigue and continuous murmur in the precordial region persisted. In angio-CT a large coronary fistula from the circumflex coronary artery with suspicion of multiple orifices to the right atrium was found. An arteriovenous wire loop was created (guidewire introduced from the aorta through the CAF was snared using a lasso catheter in the superior vena cava and exteriorized through the right femoral vein). Retrogradely an 8 F long sheath and delivery system was introduced to the end of the fistula and a 12/10 mm Cardio-O-Fix PDA occluder (Starway Comp, China, Beijing) was implanted, closing one orifice of the CAF. Another leak (orifice of CAF - 3.5 mm diameter) was closed using a similar technique with a 10/8 mm PDA Cardio-O-Fix device. Complete closure of the coronary artery fistula and disappearance of the heart murmur were observed after the procedure. The patient was discharged home 4 days later on acetylsalicylic acid 150 mg/day. During 6 months of follow-up he was doing well without any complaints or pathological symptoms. In control angio-CT performed 3 months after the procedure complete closure of the CAF was confirmed.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge