Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Analytical Toxicology 2017-Jun

Sensitive Determination of Cannabinoids in Whole Blood by LC-MS-MS After Rapid Removal of Phospholipids by Filtration.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Lambert K Sørensen
Jørgen B Hasselstrøm

キーワード

概要

Direct analysis of Δ9-tetrahydrocannabinol (THC) and other cannabinoids in crude acetonitrile extracts of whole blood by liquid chromatography-tandem mass spectrometry using pneumatically assisted electrospray ionization (LC-ESI-MS-MS) was subjected to pronounced ion suppression from co-eluting phospholipids (PLs). The interferences were mainly caused by the lysophosphatidylcholine and lysophosphatidylethanolamine classes of PLs. The PLs were easily removed from crude extracts by filtration through a sorbent with Lewis acid properties, which typically increased the THC and cannabinol (CBN) signal intensities by a factor of 5. Based on this technique, a simple high-throughput LC-MS-MS method was developed for the determination of cannabinoids in 100 μL samples of whole blood. The lower limits of quantification were 0.2 μg/L for THC, CBN, cannabidiol (CBD) and Δ9-tetrahydrocannabinolic acid A (THCA-A) and 0.5 μg/L for 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH). The mean ion suppression levels after clean-up were 10% (THC), 9% (CBN), 17% (CBD), 0% (THC-OH), 2% (THC-COOH) and 9% (THCA-A) at blood concentration levels of 1-10 μg/L. The mean true extraction recoveries were 97% (THC), 101% (CBN), 101% (CBD), 98% (THC-OH), 95% (THC-COOH) and 90% (THCA-A) at the same concentration levels. The relative intra-laboratory reproducibility standard deviations were <9% at concentrations of 1 μg/L or higher. The trueness expressed as the relative bias of the test results was within ±4% at concentrations of 1 μg/L or higher.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge