Lithuanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Canadian Journal of Veterinary Research 1986-Oct

Evaluation of a commercial creatine kinase screening test for malignant hyperthermia (porcine stress syndrome).

Straipsnius versti gali tik registruoti vartotojai
Prisijungti Registracija
Nuoroda įrašoma į mainų sritį
W N McDonell
D C Seeler
P K Basrur

Raktažodžiai

Santrauka

Two hundred and seven boars entering a Record of Performance Test Station at New Hamburg, Ontario were screened for susceptibility to malignant hyperthermia or the porcine stress syndrome. Screening tests included the determination of whole blood creatine kinase levels by a commercially available test using the method of bioluminescence and a halothane challenge. The validity of the bioluminescent or whole blood creatine kinase test as a screening mechanism for malignant hyperthermia was evaluated in boars in a field trial. The susceptibility of these animals to malignant hyperthermia or the porcine stress syndrome was unknown at the time of the study. It was determined in the initial field trial that 76.3% or 158 of the 207 boars tested by the bioluminescent creatine kinase screening test were stress susceptible. In contrast, only one boar (0.5%) reacted to a standard five minute halothane challenge. After further examination of the commercial screening test, little correlation was found to exist between the bioluminescent and Rosalki methods of creatine kinase determination. The coefficient of analytical variation for the bioluminescent method of creatine kinase determination ranged from 17.6% at a mean of 359 LU to 21.9% at a mean of 318 LU. Similarly, the coefficient for the Rosalki technique ranged from 7.1% at a mean of 324 U/L to 14.0% at a mean of 64 U/L. In addition, little correlation was found to exist between creatine kinase levels as determined by the bioluminescent method and outcome to the halothane or halothane/succinylcholine challenge, age of boars in weeks or percentage gain in weight.(ABSTRACT TRUNCATED AT 250 WORDS)

Prisijunkite prie mūsų
„Facebook“ puslapio

Išsamiausia vaistinių žolelių duomenų bazė, paremta mokslu

  • Dirba 55 kalbomis
  • Žolelių gydymas, paremtas mokslu
  • Vaistažolių atpažinimas pagal vaizdą
  • Interaktyvus GPS žemėlapis - pažymėkite vaistažoles vietoje (netrukus)
  • Skaitykite mokslines publikacijas, susijusias su jūsų paieška
  • Ieškokite vaistinių žolelių pagal jų poveikį
  • Susitvarkykite savo interesus ir sekite naujienas, klinikinius tyrimus ir patentus

Įveskite simptomą ar ligą ir perskaitykite apie žoleles, kurios gali padėti, įveskite žolę ir pamatykite ligas bei simptomus, nuo kurių ji naudojama.
* Visa informacija pagrįsta paskelbtais moksliniais tyrimais

Google Play badgeApp Store badge