International Journal of Hyperthermia 2004-Aug

Development of a phantom compatible for MRI and hyperthermia using carrageenan gel--relationship between dielectric properties and NaCl concentration.

Alleen geregistreerde gebruikers kunnen artikelen vertalen
Log in Schrijf in
De link wordt op het klembord opgeslagen
H Kato
K Yoshimura
M Kuroda
A Yoshida
K Hanamoto
S Kawasaki
K Shibuya
Y Yamamoto
M Tsunoda
M Takemoto

Sleutelwoorden

Abstract

A phantom has previously been developed containing carrageenan, agarose and gadolinium chloride (called CAG phantom) for MRI with 1.5 T. T(1) and T(2) relaxation times of this phantom are independently changeable by varying concentrations of relaxation-time modifiers to simulate relaxation times of the various types of human tissues. The CAG phantom has a T(1) value of 202-1904 ms and a T(2) value of 38-423 ms, when the GdCl(3) concentration is varied from 0-140 micromol/kg and the agarose concentration is varied from 0-1.6%. A new phantom has now been developed (called CAGN phantom), made by adding an electric conductive agent, NaCl, to the CAG phantom for use in the areas of MRI and hyperthermia research. Dielectric properties of the CAGN phantom were measured and the results of experiments were expressed by the Cole-Cole equation in the frequency range of 5-130 MHz. The relationship between the conductivity of the CAGN phantom and the concentration of NaCl was expressed by a linear function in the frequency range of 1-130 MHz. The linear function involves a parameter of frequency and, when the frequency is 10 MHz, the conductivity of the CAGN phantom can be changed from 0.27-1.26 Sm(-1) by increasing the NaCl concentration from 0-0.7%. The CAGN phantom developed can be employed in basic experiments for non-invasive temperature measurement using MRI and as a loading phantom for MRI with up to 3 T.

Word lid van onze
facebookpagina

De meest complete database met geneeskrachtige kruiden, ondersteund door de wetenschap

  • Werkt in 55 talen
  • Kruidengeneesmiddelen gesteund door de wetenschap
  • Kruidenherkenning door beeld
  • Interactieve GPS-kaart - tag kruiden op locatie (binnenkort beschikbaar)
  • Lees wetenschappelijke publicaties met betrekking tot uw zoekopdracht
  • Zoek medicinale kruiden op hun effecten
  • Organiseer uw interesses en blijf op de hoogte van nieuwsonderzoek, klinische onderzoeken en patenten

Typ een symptoom of een ziekte en lees over kruiden die kunnen helpen, typ een kruid en zie ziekten en symptomen waartegen het wordt gebruikt.
* Alle informatie is gebaseerd op gepubliceerd wetenschappelijk onderzoek

Google Play badgeApp Store badge