Transplantation Proceedings 2010-Jun

Importance of organ preservation solution composition in reducing myocardial edema during machine perfusion for heart transplantation.

Samo registrirani uporabniki lahko prevajajo članke
Prijava / prijava
Povezava se shrani v odložišče
M L Cobert
M Peltz
L M West
M E Jessen

Ključne besede

Povzetek

OBJECTIVE

Machine perfusion preservation has been used experimentally to extend the storage interval of donor hearts. We previously demonstrated that machine perfusion with glucose-supplemented Celsior preservation solution led to superior reperfusion function but resulted in increased myocardial edema compared with conventional static preservation. We hypothesized that other solutions that contain an oncotic agent, such as University of Wisconsin Machine Perfusion Solution (UWMPS), might reduce graft edema development while maintaining myocardial oxidative metabolism during long-term storage.

METHODS

Canine hearts were stored and perfused in a perfusion preservation device (LifeCradle; Organ Transport Systems) after cardioplegic arrest and donor cardiectomy. Hearts were perfused either with glucose-supplemented Celsior (which lacks an oncotic agent) or UWMPS (which contains hydroxyethyl starch) at 5 degrees C in the perfusion device over 10 hours. Oxygen consumption (MVO(2)), lactate accumulation, regional flow distribution, and myocardial water content were measured.

RESULTS

Hearts in both groups continued to extract oxygen over the entire perfusion interval. Lactate accumulation was minimal in both groups. Both solutions delivered perfusate evenly to all regions of myocardium. Heart weight increase (Celsior 31.3 +/- 4.3%, UWMPS -3.3 +/- 1.9%) and final myocardial water content (Celsior 80.2 +/- 1.3%, UWMPS 75.9 +/- 0.3%) were higher in the Celsior group (P < .005).

CONCLUSIONS

Donor hearts can be supported by a perfusion device over relatively extended storage intervals. These organs continue to undergo oxidative metabolism with little lactate accumulation. An oncotic agent appears to be important in limiting increases in myocardial water content. UWMPS appears to be superior for perfusion preservation of myocardium by reducing edema development during storage.

Pridružite se naši
facebook strani

Najbolj popolna baza zdravilnih zelišč, podprta z znanostjo

  • Deluje v 55 jezikih
  • Zeliščna zdravila, podprta z znanostjo
  • Prepoznavanje zelišč po sliki
  • Interaktivni GPS zemljevid - označite zelišča na lokaciji (kmalu)
  • Preberite znanstvene publikacije, povezane z vašim iskanjem
  • Iščite zdravilna zelišča po njihovih učinkih
  • Organizirajte svoje interese in bodite na tekočem z raziskavami novic, kliničnimi preskušanji in patenti

Vnesite simptom ali bolezen in preberite o zeliščih, ki bi lahko pomagala, vnesite zelišče in si oglejte bolezni in simptome, proti katerim se uporablja.
* Vse informacije temeljijo na objavljenih znanstvenih raziskavah

Google Play badgeApp Store badge