Journal of rural medicine : JRM 2020-Apr

Methemoglobinemia due to local anesthesia: a rare cause of cyanosis and chest pain after placement of implantable cardioverter defibrillator.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Yuksel Cicek
M Durakoglugil
Ece Usta

キーワード

概要

Although methemoglobinemia is rare in adulthood, it may have fatal consequences if unnoticed. We planned to implant an implantable cardioverter defibrillator ICD in a 50-year-old male patient for primary prevention. Following sterile draping, prilocaine 5 mg/kg (400 mg) was injected subcutaneously for local anesthesia. We injected an additional dose of 200 mg due to pain during subclavian vein puncture. A DDD-R ICD was placed successfully within approximately 40 minutes. The patient complained of sudden chest pain and dyspnea 15 minutes after bed rest and was transferred to the coronary care unit due to cyanosis and deterioration of general status. Physical examination revealed blood pressure of 110/80 mmHg, pulse rate of 110 bpm, and otherwise unremarkable signs. Peripheral oxygen saturation was determined as 83% by pulse oximeter. Possible pneumothorax and cardiac perforation were excluded by emergency chest radiograph and echocardiography. Blood gas analyses was performed to assess for methemoglobinemia, which revealed pH 7.41, pCO2 40 mmHg, oxygen saturation 98.2%, and methemoglobin 7.9% that peaked to 12.3%. Methylene blue (1%) was slowly injected over 10 minutes at a dose of 1 mg/kg. Cyanosis waned and methemoglobin values decreased to 4.1%, 2.1%, and 1.1% at 2, 8, and 16 hours following the administration, respectively. The patient was safely discharged 2 days after implantation of pacemaker. Methemoglobinemia should be considered in cases presenting with cyanosis, non-diagnostic ECG, and a discrepancy in oxygen saturation between pulse oximetry and blood gas analyses.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge